Siemens REV24 Serie Instrucciones De Montaje página 8

Ocultar thumbs Ver también para REV24 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
Note 1:
If the radio clock is not active or not present, this setting has no impact.
DE
With the radio clock active, the time signal received from Frankfurt is shifted by the value set under code 30 (time zone).
Note 2:
If the radio clock is not active or not present, the time change always takes place at 02:00 on the Sunday before the set date.
EN
With the radio clock active, the time change is shifted by the value set under code 30 (time zone).
Note 3:
FR
If the radio clock is not active or not present, the time change always takes place at 03:00 on the Sunday before the set date.
With the radio clock active, the time change is shifted by the value set under code 30 (time zone).
IT
3
Function check
a) Check the display. If there is no display, check the batteries
NL
b) "Continuously Comfort mode"
c) REV.. in heating mode: Set the temperature setpoint to a level above
ES
the displayed room temperature (see operating instructions)
REV.. in cooling mode: Set the temperature setpoint to a level below
the displayed room temperature (see operating instructions)
PT
d) The relay and thus the actuating device must respond within
1 minute. Symbol
CS
·
Check actuating device and wiring
·
In heating mode, the room temperature is possibly higher than the
HU
adjusted temperature setpoint, in cooling mode possibly lower
e) Set temperature setpoint of "Continuously Comfort mode"
required level
PL
f)
Select the required operating mode
SV
FI
DA
TR
EL
8/50
, read the temperature displayed
appears on the display. If not:
4
Reset
User-defined settings:
Press simultaneously
All temperature and time settings of the slider positions are reset to
their default values (refer to section "Factory settings" in the operating
instructions). The settings made on the expert level will remain
unchanged.
The clock starts at 12:00, the date on 01-01-08
(01 - January - 2008). During the reset time, all sectors of the display
are illuminated and can thus be checked.
All user-defined settings plus those made on the expert level:
Press simultaneously the DIP switch reset button,
seconds:
After this reset, all factory settings will be reloaded. This applies to
to the
both the slider settings and the settings made on the expert level.
Notes
·
The controller is classified as a device of software class A and
designed for use in environments with normal degree of pollution
2015-02-27
,
and
for 3 seconds:
and
CE1G2205xx
for 5

Publicidad

Tabla de contenido
loading

Tabla de contenido