4.
Lift the housing into place and position end of mounting
arm onto leveling steps so that housing is level. Care
must be taken so arm does not inadvertently strike
internal components. (Figure 3. & Figure 4.)
5.
Using a 9/16" socket tighten the four clamp mounting
bolts to 16-18 ft-lbs.
Wiring (Figure 6.)
1.
Pull service wires through mounting arm and into
housing approximately 10" .
a. Three-terminal block (2-wire service): Connect line
service lead to terminal that is connected to black
factory-installed wire. Connect neutral service wire to
terminal that is connected to white factory-installed
wire.
b. Three-terminal block (3-wire service, 2 lines,
1 ground): Connect 1 line service lead to terminal
that is connected to black factory-installed wire.
Connect other line service lead to terminal that is
connected to white factory-installed wire. Connect
ground service lead to terminal that is connected to
green factory-installed wire.
c. Three-terminal block (3-wire service, 1 line, 1 neutral,
1 ground): Connect line service lead to terminal that
is connected to black factory-installed wire. Connect
neutral service wire to terminal that is connected to
white factory-installed wire. Connect ground service
wire to terminal that is connected to green factory-
installed wire.
d. No terminal block (3-wire service, 2 lines, 1 ground):
Connect 1 line service lead to black factory-installed
wire. Connect other line service lead to white
factory-installed wire. Connect ground service lead to
green factory-installed wire.
e. No terminal block (3-wire service, 1 line, 1 neutral,
1 ground): Connect line service lead to black
factory-installed wire. Connect neutral service wire
to white factory-installed wire. Connect ground
service wire green factory-installed wire.
N
ote:
Terminals are numbered at the wire entrance of the
terminal block. See wiring diagram for additional
wiring details.
2.
Ensure all wiring is secure and reconnect the quick
disconnects.
3.
Return door to hinge if removed and swing the housing
door into closed position and secure latch or retighten
screws to 14~16 in-lbs.
Installation Instructions - Verdeon/VRDN
Quick Disconnects
in Rear of Door
(Not Shown)
Figure 4.
Figure 5.
Ground Lead
Three-Postion
Terminal Block
Figure 6.
COOPER LIGHTING SOLUTIONS
Install Direction
-110°
Neutral Lead
Hot Lead
IB521002EN
Installation instructions
3