Dip-Switch Functions - Vimar RS16.P Guía Rápida Para El Instalador

Ocultar thumbs Ver también para RS16.P:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
RS16.P

DIP-switch functions

DIP
Function
DIP 1
Close immediately
DIP 2
Automatic closing
DIP 3
Step-step logic
DIP 4
Apartment block
DIP 5
Slowdown distance
DIP 6
Input 63 function
DIP 7
Action speed
DIP 8
Photo-test
LED functions
LED
Status
PWR
OFF
ON
MRX
1 blink
2 blinks
3 blinks
4 blinks
5 blinks
10 blinks
51
OFF
ON
52
OFF
ON
61
OFF
ON
62
OFF
ON
63
OFF
ON
OFF
SW1
ON
OFF
SW2
ON
Changing the programmable parameters
The control panel is programmed by default with the following parameters:
- automatic closing:
30 s
- opening direction:
to the right
- pedestrian opening position: 1 m
Notes: do not change the wiring for the electric motors. To reverse the opening direction, follow the procedure described below.
4
Status Description
OFF
Close immediately off
ON
Close immediately on:
The engagement and subsequent disengagement of the photocell when closing, while opening or during
the pause time causes the gate to reclose immediately at least 3 s after full opening, regardless of the set
automatic closing time.
OFF
Automatic closing off
ON
Automatic closing on
OFF
2 steps: step-by-step (term. 51 and radio) with logic in 2 steps (open - close - open)
ON
Step-by-step command (term. 51 and radio) with logic in 4 steps (open - stop - close - stop - open - stop)
OFF
Apartment block off
ON
Apartment block on (while the gate is opening, you cannot stop the movement with a radio command or with
inputs 51 (step-by-step) and 52 (pedestrian).
With automatic closing on (DIP-switch 2 = ON) and the gate open, an additional step-by-step command
(terminal 51 or radio command) renews the pause time and if input 51 remains engaged the control panel
suspends the pause count until the input is disengaged (for connecting any coils or a timer).
OFF
Slowdown distance at 10% of the travel
ON
Slowdown distance at 20% of the travel
OFF
Input 63 configured as photocell (PH)
ON
Input 63 configured as safety edge (BAR)
OFF
Action speed high
ON
Action speed low
OFF
Photo-test off
ON
Photo-test on
At the start of each action, the control panel checks the operation of the photocells.
It requires specific wiring
Description
Mains power supply not present
Mains power supply present
Saving a new remote control
Saving a remote control already in memory
Deleting a remote control
Radio memory full
Attempt to store a remote control with a different code from the one used to set the receiver
Complete deletion of the radio memory
Step-by-step input (term. 51) not engaged
Step-by-step input (term. 51) engaged
Pedestrian input (term. 52) not engaged
Pedestrian input (term. 52) engaged
Stop contact (term. 61) open (engaged)
Stop contact (term. 61) closed (not engaged)
Photocell engaged when closing (term. 62 open)
Photocell not engaged when closing (term. 62 closed)
Photocell or safety edge engaged (term. 63 open)
Photocell or safety edge not engaged (term. 63 closed)
Limit switch 1 (corresponding to the right limit switch bracket marked DX) not used
Limit switch 1 engaged
Limit switch 2 (corresponding to the left limit switch bracket marked SX) not used
Limit switch 2 engaged
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido