2.3.3. Setting the battery alarm threshold
The battery alarm allows you to monitor the supply voltage to your installation. This is
important, particularly for good sounder performance.
menu
Press
, then once again on
threshold page, then adjust the required value of the threshold using
the
and
Press
to exit setup mode, or time out after 10 seconds.
2.4. Configuration
2.4.1. Keel offset
The depth displayed on the Multi display represents the distance between the probe mounted
on the hull and the bottom, plus or minus the keel offset:
For a positive offset, the depth is measured from a point located above the probe
(Depth = distance between probe and bottom + Offset).
For a negative offset, the depth is measured from a point located below the probe
(Depth = distance between probe and bottom - Offset).
To adjust this offset:
menu
Press
for 2 seconds, then on
displayed, then adjust the required value using the
keys.
Press
to exit setup mode, or time out after 10 seconds.
2.4.2. Speed damping
A damping coefficient is available to the user for boat speed. Depending on navigation
conditions, this parameter can be adjusted to between 1 and 30.
menu
Press
for 2 seconds, then on
is displayed, then adjust the required value using the
keys.
Press
to exit setup mode, or time out after 10 seconds.
menu
keys.
menu
menu
Installation and Operation Manual S400 series
to display the "bAt" low
until the "kEEL offset page is
until the "dAMP" setup page
and
and
13