Installation
Rough-In Dimensions for Supplies and Drain
Notes
Maximum flow rate required to washfountain is 1.5 GPM. Size supply lines accordingly.
Supplies from Below: Stub up 2-1/2" (64).
Supplies from Above: Supplies must be located on centers of dimensions shown to pass
through washfountain shroud and sprayhead.
Drain through floor: Stub up 3" (76).
Supplies from Below or Through Wall
Type A
Off-line vent (P-Trap
supplied by Installer.)
Top View
2-9/16"
(65)
6-3/4"
(298)
7-15/16"
(202)
11-3/4"
(298)
When running supplies and drain through wall, use same horizontal measurements as shown in Top View.
Postion openings above the finished floor, at the following dimensions (to center):
Drain:
Floor-mounted units: UPC and IPC restrict the vertical
distance from the fixture outlet to the trap weir to not more
than 24" (610). Check state and local codes for variances.
Bradley • 215-784 Rev. P; ECN 14-00-007
Type H
Centrally rising vent - passes
through center of unit
(P-Trap furnished).
11-3/4"
(298)
Optional Wall
DRAIN
12-1/16"
(306)
C
H
12-1/16"
(306)
18-7/16"
(468)
Standard Height: 19-1/4" (305)
Juvenile Height: 15-1/4" (387)
SN2013/AST4, SN2013/AST4-F, SN2033/AST4
Type B
Centrally rising vent - passes
through center of unit
(P-Trap furnished).
6-3/4"
(298)
11-3/4"
18-7/16"
(298)
(468)
Supplies: Standard Height: 12" (305)
Juvenile Height: 8" (203)
Key
1/2" Supply: Nominal Copper Tube
1/2" Supply Through Wall (Optional): Nominal Copper Tube
1-1/2" NPT Drain
Supplies from Above
Top View
11-3/4"
(298)
Optional Wall
DRAIN
10-5/16"
(262)
C
H
10-5/16"
(262)
11-1/2"
(292)
8/15/2014
(mm)
Type O
Off-line vent (P-Trap
supplied by Installer.)
11-1/2"
(292)
5