Bradley SN2013/AST4 Manual Del Usuario página 7

Fuente de lavado de esquina sentry con control de válvula de aire
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
STOP!!! If installing optional Shroud/Slip Ring or Towel Dispensers, complete
those installations before proceeding to Step 3 (see next page).
3
Connect Drain
Off-Line Vent (Type A or O): Connect 1-1/2" P-Trap and
drain piping (supplied by installer) to the drain spud.
Centrally Rising Vent (Type B or H) or models with
optional paper towel dispensers: Connect the vented
P-Trap (provided) and drain piping as shown:
4
Turn on Water, Test and Adjust Unit
Check to make sure stop valves are open before
turning on water.
A
Turn on water supply and check for leaks. Activate
each push/foot button to purge air from the lines.
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
Bradley • 215-784 Rev. P; ECN 14-00-007
SN2013/AST4, SN2013/AST4-F, SN2033/AST4
Strainer
Drain Spud
Tailpiece
P-Trap
B
Adjust air-valve meter timing, if desired
(hand-operated units only).
(Hand-operated push button only)
C
C
H
1-1/2" NPT Vent Pipe
(supplied by installer)
1-1/2" NPT Tee
1-1/2" NPT Close Nipple
1-1/2" Drain (supplied by
-
+
Air Metering Timer
Loosen the cap screw about
¼" (4–6 turns) and lift up the
cover (do not remove).
Using the cover, turn
the cartridge gently until
D
desired water temperature
is reached. Do not turn past
stops as this may damage
the unit. Push the cover
down and tighten the screw.
8/15/2014
installer)
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sn2013/ast4-fSn2033/ast4

Tabla de contenido