PRASTEL FSLIMRFRX Manual Del Usuario página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

FSLIMRFRX
Activating/deactivating the receiver (F1)
With this function it is possible to select the status of the receiver. In OFF status the receiver is still working, but all alarms coming from the
barriers will be ignored. The ON status is signalled by the presence of 3 dots on the display (". . .").
1.
Simultaneously press keys INC (blue) and DEC (red).
2.
Press key FUN (yellow) to access the function selection menu.
3.
Select function F1 by pressing keys INC and DEC.
4.
Confirm selection by pressing the VAL (green) key; current parameter value appears on the display.
5.
Select via keys INC and DEC the value "On" (receiver activated) or "Off" (receiver deactivated)
6.
Confirm by pressing key VAL; display returns to function selection and the new parameter is stored.
7.
Simultaneously press keys INC and DEC to exit from programming mode.
Activating/deactivating the receiver by remote control
It is possible to learn up to 30 remote controls to activate/deactivate the receiver. The remote controls can be learnt into or deleted from
locations 501 – 530, with the same procedure used to learn or delete the barriers.
After learning, use button 1 of the remote control to activate and button 2 to deactivate the receiver.
Both activation and deactivation are signalled by the receiver's buzzer (activation: one long beep, deactivation: 3 short beeps).
Activating/deactivating supervision check (F2)
The FSLIMRF barriers transmit a supervision signal at intervals of 1 hour.
If the supervision check is activated, the FSLIMRFRX receiver checks the presence of this signal. If no signal is received by a barrier for 2
hours, the "no supervision" contact (relay 4) is activated and the event is saved in the memory.
To activate/deactivate the supervision check proceed as follows:
1.
Simultaneously press keys INC (blue) and DEC (red).
2.
Press key FUN (yellow) to access the function selection menu.
3.
Select function F2 by pressing keys INC and DEC.
4.
Confirm selection by pressing the VAL (green) key; current parameter value appears on the display.
5.
Select via keys INC and DEC the value "On" (supervision check activated) or "Off" (supervision check deactivated)
6.
Confirm by pressing key VAL; display returns to function selection and the new parameter is stored.
7.
Simultaneously press keys INC and DEC to exit from programming mode.
Activating/deactivating the TEST mode (F3)
The TEST mode is intended to make easier the installation of the system. In TEST mode, when the receiver receives a transmission from a
barrier already in memory it doesn't activate any relay but generates a beep.
To use the TEST function:
- learn the barriers being near the receiver
- activate the TEST mode
- place the barrier where you intend to install it
- make a transmission by means of the "ALIGN/RADIO" button of the barrier. If the barrier is in within the receiver's range the receiver will
generate a beep.
The TEST mode is signalled by the presence of 3 lines on the display ("- - -").
1.
Simultaneously press keys INC (blue) and DEC (red).
2.
Press key FUN (yellow) to access the function selection menu.
3.
Select function F3 by pressing keys INC and DEC.
4.
Confirm selection by pressing the VAL (green) key; current parameter value appears on the display.
5.
Select via keys INC and DEC the value "On" (TEST mode activated) or "Off" (TEST mode deactivated)
6.
Confirm by pressing key VAL; display returns to function selection and the new parameter is stored.
7.
Simultaneously press keys INC and DEC to exit from programming mode.
Selecting operation mode and relay timing (F4) (F5) (F6) (F7)
1.
Simultaneously press keys INC (blue) and DEC (red).
2.
Press key FUN (yellow) to access the function selection menu.
3.
Select function F4 (relay 1), F5 (relay 2), F6 (relay 3) or F7 (relay 4) by pressing keys INC and DEC.
4.
Confirm selection by pressing the VAL (green) key; current parameter value appears on the display.
5.
Select the value to be assigned to the parameter by pressing keys INC and DEC. Set a value between 1 and 180: the relay will operate
in monostable mode, with activation time corresponding to the set value, in seconds. In the case of alarm and tamper relay, if a value
of 000 is set the relay will operate in bistable mode; the relay activates when at least one barrier is in "alarm" or "tamper" status, and
deactivates when all the barriers that previously had sent the "alarm" or "tamper" signal send the "end of alarm signal". The alarm
status of the barrier is shown on the display with decimal points: alarm
6.
Confirm by pressing key VAL; the display shows the currently selected contact mode (N.O. or N.C.)
7.
Select "NC" (normally closed) or "NO" (normally open) by pressing keys INC and DEC
8.
Confirm by pressing key VAL; display returns to function selection and the new parameter will be stored.
9.
Simultaneously press keys INC and DEC to exit from programming mode.
Deleting all barriers (F8)
Deletion of all codes avoids having to scroll all locations and having to delete one barrier at a time in the case the memory has to be fully
cleared.
1.
Simultaneously press keys INC (blue) and DEC (red).
2.
Press the FUN (yellow) key to access the function selection menu.
3.
Select function F8 by pressing keys INC and DEC.
4.
Confirm by pressing the VAL (green) key. The word "Can" appears on the display.
5.
Confirm again by pressing the VAL key. The FSLIMRFRX fully deletes the code area and the historic area. All other stored parameters
(relay times, supervision, etc.) remain unaltered.
ENGLISH
left decimal point ON, tamper
ISFSLIMRFRX_12_07.doc
central decimal point ON.
6

Publicidad

Tabla de contenido
loading

Tabla de contenido