Operating manual
TRIGGER COMMAND CONNECTOR
DB
P
L
Cabling diagram for the SRL18 torch.
Torch double button +
potentiometer

REMOTE CONTROL

The analog remote control operates in TIG and MMA processes.
Ref. 045699
Connection
1- Plug the remote control into the connection at the back of the machine.
2- The HMI detects the presence of a remote control and offers a selection choice accessible by wheel.
Connections
The product is equipped with a female socket for a remote control.
The specific 7 pin male plug (option ref. 045699) allows the connection of different types of remote control. For the cabling layout, please see the
diagram below.
Foot pedal
Operating:
• Manual remote control (option ref. 045675):
The remote control enables the variation of current from 50% to 100% of the set intensity. In this configuration, all modes and functions of the ma-
chine are accessible and can be set.
• Foot pedal (option ref. 045682):
The foot pedal allows the current to be set from 10% to 100% of the set current. In TIG, the welding machine only operates in 2T mode. The
upslope and downslope are not automatically managed by the current source, and are controlled by the user with the foot pedal.
Translation of the original
instructions
1
P
5
torch
2
4
L
DB
torch
2
torch
3
Torch type
Torch double button
G
F
A
E
B
D
C
External view
Electric diagram according to the remote control type.
Manual remote control
4
3
5
2
6
1
NC
Electric diagram based on type of torch used.
Wire description
Common/Earth
Torch with trigger
Common/Potentiome-
D
045682
C
B
045675
A
Wire description
10 V
Cursor
Common/Earth
Switch
PROTIG 201 DC FV
DB torch
3
4
L torch
2
2
DB + P
5
torch
1
Pin
2 (green)
Button 1
4 (white)
Button 2
3 (brown)
2 (grey)
ter earth
10 V
1 (yellow)
Cursor
5 (pink)
Pin
A
B
C
D
31