OPERATION
• Activate by pressing the push-button control.
• Temperature control by rotating the push-button control.
• Automatic timed shut-off after ~30 seconds (+5/-10 at 3 bar according to the European Standard EN 816).
• Supply with cold water and hot water between 55-85°C (with a minimum temperature difference of 50°C between
the hot and cold water).
• The products are designed to withstand the thermal and chemical shocks as described by current guidelines.
• Pressure: 1 - 5 bar (100 - 500kPa), we recommend 3 bar (300kPa).
Maximum pressure differential at the inlets: 1 bar.
INSTALLATION
Do not remove the non-return valves integrated in the inlets in any circumstance.
THE INSTALLER MUST ENSURE:
• THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF TO PREVENT ANY INGRESS OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING (E.G. CONDENSATION, RUN OFF, LEAKS,
ETC.) HAS AN EXTERNAL DRAINAGE POINT TO PREVENT ANY STAGNATION;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL OR
THE WALL PLATE AND THE MIXER AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT
UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
ADJUSTING THE FLOW RATE (FIG. O)
• The flow rate is pre-set at the factory at 12 lpm at 3 bar for showers (models fitted with ROUND shower heads are
set at 6 lpm). The flow rate can be adjusted without shutting-off the water supply or removing the mixer.
REMEMBER
• Our mixers/taps/valves must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency of
maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the mixer/tap/valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
MAINTENANCE (FIG. P and Q)
We recommend an annual check of the following items:
• Non-return valves and filters: de-scale and replace worn or damaged parts.
• Inter-changeable cartridge: de-scale internal parts and replace worn or damaged parts.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer/tap/valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.