Emptying And Service - Forch 6000 0210 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
Observe the max. filling amount (see Technical Data) and the correct dosing given by the
spray producer.
Screw valve body (B) back in and pump up the device. Observe the safety / pressure
relief valve (A) during pumping. Peak pressure is reached when the safety / pressure
relief valve is triggered. Any excess pressure will escape through the safety / pressure
relief valve.
The spraying process is initiated by pressing the push button (G) on the valve body.
Releasing the push button (G) immediately interrupts the spraying process.
Pump up the unit again once the pressure has dropped to around 1.0 bar so as to en-
sure a con sistent distribution of the sprayed liquid.

Emptying and Service

Any residual pressure in the tank can be vented by lifting up the knob on the safety /
pressure relief valve (A).
Unscrew the pomp carefully, at first only a few turns by left-hand rotation, so that com-
pressed air being still in the tank can escape. Only then unscrew the pump completely
and take it out of the tank.
Empty and wash out the unit after use.
Note! Any remaining liquid in the tank can be emptied out completely through the filler
opening (in case of liquids hazardous to waters see chapter "Important safety instructions"
and observe the instructions of the liquid manufacturer).
The type of flushing liquid to be used and how it is to be disposed of will depend on the
details given by the manufacturer of the liquid to be sprayed. Also consider whether the
tank is resistant to the flushingliquid.
The pump will last much longer if the pump O-ring is lubricated from time to time with
a little re si n- and acid-free grease.
If foaming is no longer effective, check whether the air inlet bores in the connecting
nipple(E)are clogged, clean them if required.
Note! Above-average use due to manner of operating (including the tranport to the place of
operation and the storage when not using the sprayer), influences of the surroundings (of
the place of operation and the storage place), inadequate maintenance and care may lead
to an early wear of the sprayer. Therefore, the sprayer should be checked for secure and
serviceable state before use. It should at least be checked for externally visible damages.
Expecially when there occure damages which endager the security, at least however after
2 years, the sprayer should specially be examined by one of the manufacturer's service
stations.

Publicidad

Tabla de contenido
loading

Tabla de contenido