Instruct employees in the use of the Eyewash Station.
Regular training will keep employees aware of the
location and proper use of eyewash devices.
• The sooner eyes are flushed, the less likelihood of
injury.
• The unit is for emergency use only. Tampering with
the eyewash station may cause it to be empty when
needed.
In cases of severe eye contamination, the victim may
need assistance to flush the eyes.
1.
Start the fluid by pulling strap upward. (See Figure 12)
Figure 12
1.
Inspect all eyewash stations weekly to ensure proper
operating conditions. Inspection records must be
kept with the unit.
2. All eyewash devices must be cleaned and drained
at least once every six months to inhibit bacterial
growth.
3. Replace cartridge if expiration date is near or past.
4. Failure to clean and drain unit may result in
contaminated flushing solution.
NOTE: Saline Cartridges contain salt, which can
cause a white residue on the eyewash body.
Remove by wiping with a damp cloth.
PAGE 4 OF 12
OPERATION
2. Lower head into flow. (See Figure 13)
Figure 13
3. Using thumb and forefingers, fully open eyelids and
flush eyes until flow stops.
4. Empty cartridge can be replaced to extend flushing
time.
5. Victim should proceed to a primary flushing unit
after initial flush with this secondary unit.
6. After flushing, seek medical attention immediately.
7.
Replace empty unit with new cartridge.
MAINTENANCE
To replace solution:
• Drain fluid by pulling strap and allowing it to empty.
• Remove spent cartridge.
• Place pull strap over nozzles.
• Replace cartridge as detailed in "Installation"
(pages 2-3).