Installation And Assembly; Anchoring And Levelling The Equipment; Connections - Astralpool Glassy L Manual De Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
2

INSTALLATION AND ASSEMBLY

NOTICE:
Read the entire manual carefully before installing the equipment.
-
When you receive the equipment, check that all items are in good condition.
-
Identify all components prior to their installation.
-
2.1

ANCHORING AND LEVELLING THE EQUIPMENT

NOTICE: Risk of damage to the equipment. The maximum water level (⑦) when the
equipment is in operation is 4 cm below the opening in the upper part of the cover (①).
Components required to anchor the equipment (④):
Component
Chemical anchor: sleeve and AISI 316 M10 threaded rod
Flat washer, DIN 9021 Ø10 A4
DIN 934 M10 A4 Nut
1) Cement the threaded rods into the pool bottom.
2) Attach the equipment to the threaded rods and level it
use two nuts and a washer below it (with the washer on top)
use one nut and a washer above it.
2.2

CONNECTIONS

NOTICE: Risk of damage to the equipment. Clean all tubes before connecting and starting-up
the equipment.
Risk of damage to the equipment.
NOTICE:
equipment.
NOTICE: Risk of damage to the equipment. All electrical connections should use resin-filled
connections or IP68 connections. Check that all IP68 connections are properly closed so that
no water can get in. The electrical components can be damaged if inundated and this may
void the guarantee.
Risk of damage to the equipment.
NOTICE:
the relay and the jumping function positive drive cable.
1) Models 66559, 66560, 66561 and 66562: Connect the illumination control cables. ID
label on the cable end: 24 V DC - DMX (③, connect to the DMX driver).
2) Models 66560 and 66562: Connect the jumping control cables. ID label on the cable
end: 24 V DC - CUT (①, connect to the jumping function water cut-off relay).
Installation, operation and maintenance manual; Glassy Jet
Quantity
Install a 130 µm filter in the water supply to the
Install a 2-Amp fuse in the connection between
Fountain units
3
6
9
[en]
17

Publicidad

Tabla de contenido
loading

Productos relacionados para Astralpool Glassy L

Este manual también es adecuado para:

Glassy s6656266560665616655967307 ... Mostrar todo

Tabla de contenido