Troubleshooting Guide

PROBLEM
1. No water flow from either hot or
cold water supply hose:
1a. MULTI COLOR LED: Green/Blue
YELLOW LED: OFF
RED LED: OFF
1b. MULTI COLOR LED: Green/Blue
YELLOW LED: OFF
RED LED: ON
This indicates that the valve did
not open
1c. MULTI COLOR LED: Green/Blue
YELLOW LED: OFF
RED LED: BLINKING
1d. ALL LEDs OFF
2. No water flow from one hose -
(either Hot or Cold):
MULTI COLOR LED: ON
YELLOW LED: ON
RED LED: OFF
3. MULTI COLOR LED: ON
YELLOW LED: ON
RED LED: OFF
4. Unit feels warm
5. Unit cycles ON/OFF
6. Can't connect to WiFi Network
7. RED LED Blinking
8. MULTI COLOR LED Blinking
BLUE
9. MULTI COLOR LED Blinking
RED
IS-A2C-SC-IntelliFlow 2102
SOLUTION
1. Plug washing machine into IntelliFlow and turn on washing machine.
2. Unplug the leak sensor, wait for the blinking red light and replug it in.
3. Start the wash cycle.
4. If not working, confirm that the washing machine is working
1. Leak sensor has detected water.
2. Ensure that the washing machine is off
3. Unplug IntelliFlow from the electrical outlet
4. Check for broken or leaking hoses or water leaks
5. Correct problem, dry off the sensor, then re-insert plug into outlet to
reset valve.
6 Turn on the washing machine.
1. IntelliFlow/IntelliTime internal timing circuit has timed out.
When the Yellow LED is Off, turn off the washing machine to reset the
timing circuit.
2. Unplug and then plug back in sensor.
3. Turn on washing machine.
1. Plug IntelliFlow into electrical outlet.
2. Check electrical outlet for power (reset ground fault).
1. Service strainers on washing machine hoses.
2. Service strainers on IntelliFlow (see figure below).
Caution prior to servicing strainers, first remove power to IntelliFlow by
unplugging, then shut off both hot and cold water supply to IntelliFlow.
Strainer
O-Ring
Some washing machine models include circuitry that causes a slight cur-
rent draw at all times. These models when connected to the IntelliFlow
can cause the water supply to be energized continuously (Yellow LED:
ON). The IntelliFlow can be reset by unplugging and reinstalling the leak
sensor. If this does not resolve this issue, the use of the A2 IntelliTimer is
required with the system in use.
This condition is normal. Internal operating temperatures may cause unit
to feel warm to the touch.
Installation in a horizontal position can cause abnormal overheating of
the unit which causes this cycling condition. Unit must be installed in an
upright position as shown on pages 2 and 3.
Check if WiFi is 2.4 GHz. IntelliFlow is not compatible with
5 GHz WiFi.
Make sure that the Multicolor LED is Blue. If it isn't, press & hold the
button for 3 seconds to enable Wi-Fi (Blue/blinking blue).
Ensure there is sufficient WiFi signal strength, and for any firewall issues
blocking communication.
Indicates sensor is not plugged in. Plug in the sensor.
Check internet connectivity on your router.
Call Watts Technical support.
Multi color LED
Yellow LED
Red LED
© 2021 Watts