Problems
Signals
PRESFLO
®
will not turn on
The pump will
not start when
a tap is turned on
The pump
delivers no or low
pressure
The pump stops
and starts
repeatedly
The pump will
not stop
= On
= Off
Exploded view of
1 - Circuit board cover
spare parts
2 - Sensor kit
3 - Circuit board
Attention: when orde-
4 - Valve kit
ring spare parts, always
5 - Two-pieces joint with OR
state the position n°
6 - Cable bushings
from the diagram below
7 - Accumulator adapter
and the product code
8 - Water accumulator
number found in the
pressure-flow regulator
technical data table.
Article
CODE:
V00103101
~230 / 50-60
V / Hz:
16 A
I max:
Version
B
SN 1506003
Possible causes
No power
PRESFLO
model with an inadequate
®
start-up pressure (Pm) for the chosen
application.
Faulty electrical connections or
pump out of service
PRESFLO
"STAND-BY"
®
PRESFLO
in temporary shut down
®
due to "DRY RUNNING" due to lack
of water
Maximum pump pressure is
insufficient
PRESFLO
in temporary shut down
®
due to "FREQUENT START-UP"
PRESFLO
stops due to "OVERCUR-
®
RENT"
Filters or pipes may be partly blocked Check the water pipes
PRESFLO
's valve will not open
®
completely
Leaks within the system (less than
the shut-off flow rate Qa)
The flow rate is higher than the
shut-off flow rate (Qa)
PRESFLO
's check valve will not
®
close or is damaged
= Flashing
5
4
8
7
6
Solutions
Check the electrical connections
Relocate PRESFLO
Install a model with a higher start-up pressure (Pm)
Check the electrical connections and that the pump
is working
Reset PRESFLO
®
Wait for the automatic restart or press START to
restart manually (See Operation, point 4a)
Replace the pump with one with more suitable
characteristics
Install a model with a lower start-up pressure (Pm)
Wait for the automatic restart or press START to
restart manually (See Operation, point 4b). Remove
any cause of leakage from system or install an
expansion tank
Check if the setting of the maximum current (Imax)
is congruent with the data of the pumps' rating
plate. If after manually restarting the pump after
correctly setting PRESFLO
anomaly, check that the motor has no mechanical
or electrical problems.
Check that the valve is not blocked by any foreign
objects and clean if necessary
Check the hydraulic connections and repair any
leaks. If a leak cannot be repaired, install an
expansion tank
Make sure that all taps are turned off and that
there are no leaks within the system
Check that the valve is not blocked by any foreign
objects and clean if necessary