Berker 7531 00 01 Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
Temporary change to manual operation:
Depress the
key briefly until LED A1 or LED A1 and A2 are
flashing. The switching state is indicated by LED 1/
LED
remains off.
The actuator is now in the manual mode and the control via the EIB
is disabled. If no key is depressed for more than 5 seconds, the
actuator quits the manual mode and goes automatically back to
bus operation.
=
>
Keys 1/
and 0/
can be used for switching the output indicated by
LEDs A1 – A16. The switching state itself is indicated by the LED
beside the keys.
A short press of the
key selects the other outputs which are to
be switched or whose status is to be indicated.
When all outputs A1 – A16 have been selected once, the actuator
automatically quits the manual mode.
Manual operation
Manual operation
Central shut-off function:
In the permanent manual operation, the actuator has a central
=
>
and 0/
.
shut-off function.
To activate the central shut-off function, depress the OFF key
briefly. All relays (switching and shutter functions) are deactivated.
Important: Central shutoff is not available for temporary manual
operation.