LF ELETTRONIC Manual De Instrucciones página 29

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SALT ALARM ON - Problems, possible causes and remedies
There is salt on the tub but the salt alarm lights when the systems shifts to C4
Start manual regeneration and make sure that CL is shown on the display during phase C2.
If this does not happen:
1 - Check connection where the regenerating agent operates. Air leaks may hamper suction and
chlorine production.
2 - Check brine quality/concentration. Remember that it takes around one hour to form a solution
that is sufficiently saturated to be detected by the system (CL) and start chlorine production.
3 - Check electrical connections on the back of the programmer and the correct insertion of the plug
into the electrode-chlorinator.
4 - Check the cleaning of electrode-chlorinator surface and remove any deposits with the tip of a
screwdriver or something slightly abrasive like fine sand-paper (the most common problem).
1)
Disconnect electric connection from chlorine producing cell.
2)
Unscrew the chlorine producing cell by using an
appropriate tool (spanner or pliers).
Water softener ELETTRONIC with AUTOTROL digital head logix
27

Publicidad

Tabla de contenido
loading

Tabla de contenido