PERIODIC CHECKS
AFTER THE FIRST 6-12 MONTHS, and then EVERY 6-12 MONTHS:
Clean the salt container following the procedure hereunder:
• Remove the remaining salt from the bottom;
• Clean all the walls of the container from muddy, oozy or dry salt deposits;
• Rinse several times with running water using a disinfectant and a sponge;
• Rinse again, add the same quantity of water and then add the salt.
Periodically clean the washable cartridge of the pre-filter by removing all impurities from the bottom
and from the surface of the cartridge. It is sufficient to use running water.
________________________________________________________________________________
TROUBLE SHOOTING

Problems, causes and solutions

PROBLEMS
Display does not show time alternate to
the quantity of water shown in available
cubic metres (only volumetric version)
Display does not show correct time
Time on display continues going on
Display shows different data from the
time
Display does not show the stream icon
Regeneration starts at a wrong time
Water softener ELETTRONIC with AUTOTROL digital head logix
Power supply failure
Plug does not work
Defective transformer
Defective circuit board
Time regulation unset
Continuous lack of power
Programmer defective
Defective internal connections in the
programmer
Electrical interference
Detective circuit board
By pass valve open
Counting cable not correctly inserted
in the turbine.
Impurities in the internal turbine counter
Detective circuit board
Timer set up incorrectly
Regeneration time set up incorrectly
CAUSES
SOLUTIONS
Connect
Repair the plug
Replace the transformer
Replace the programmer
Reset time
Reset time
Replace the programmer
Replace the programmer
Switch off power and switch on after
setting right time
Replace programmer
Close by pass
Put Insert bayonet of the counting cable
in the turbine section
Check and clean turbine counter
Replace programmer
Set up the timer
Adjust regeneration time