General description: The electronic control panel Elpro 70/3 Plus, new generation, is designed to operate the sliding gate operators MEC 200. Power supply is 230-400V single- and
three-phase. It is built in full compliance with the Low Voltage 2006/95/CE and Electro-Magnetic Compatibility Regulations 2004/108/EEC - 92/31/EEC. Fitting operations are recommended
to be carried out by a qualified technician in conformity to the existing safety standards. The manufacturing company declines any responsability for incorrect handling and applications;
also, it reserves the right to change or update the control panel any time. Failure to follow the installation regalations may result in serious damages to properties and persons.
PLEASE NOTE:
- The control panel is fitted inside Mec 200.
- Make sure that the power supply to the electronic programmer is 230V ±10% or 400V ±10%.
- Make sure that the power supply to the Electric Motor is 230V ±10% or 400V ±10%.
- For distances of over 50 metres we recommend using electric cables with bigger sections.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
2
- Use 1.5 mm
section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50 m.Use 1 mm
limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 11 and 12 if no photocells are required.
- Bridge terminals 5 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
Dip-Switch:
1= ON Photocells. Stop on opening
2= ON Radio. No reversing on opening
3= ON Automatic closing
4= ON Preflashing activated
5= ON Radio.Step by step, stop in between
6= ON Deadman Control (Dip 4=OFF n Dip 3=OFF)
7= ON No light during dwell time
8= OFF. Blank
In case of failure of the panel:
- Make sure that the power supply to the electronic programmer is 230V ±10% or 400V ±10%
- Make sure that the power supply to the Electric Motor is 230V ±10% or 400 V ±10%
- For distances of over 50 metres we recommend using electric cables with bigger sections.
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control panel to the electric motor
4138
Drwg. No.
PLUS
SINGLE-/THREE-PHASE FOR SLIDING GATE OPERATORS MEC 200
CARD CONNECTOR
L3
L5
T2
DWELL TIME
T3
PEDESTRIAN TIME
from 5 to 150s
from 3 to 30s
-
-
-
+
+
T1
MOTOR RUN TIME
-
from 5 to 150s
+
L1
RADIO
PLUG-IN
L10
L8
L2
L4
L6
L7
L9
TRANSFORMER
T4
F6=630mA for 24V
protection
EXT TIME (Electric lock &
+
Courtesy Light) from 2 to 255s
11 12 13
14
15
16 17
18
19
DIP-SWITCH
ON
OFF
4 5 6 7 8
1
2
3
F4=630mA
400V
Transformer
Protection
230V
20 21
22
23
F5=1A Flashing
Lamp Protection
24
25
M
2
®
26
27
28
29
section wires for
5