GB
®
LOW VOLTAGE ELECTRICAL CONNECTIONS
Photocell:
11 12
PHOTOCELL
CONTACT
Push Button Switch:
Radio Contact:
- Open/Close (Standard)
- Travel reversing on pulsing
- Step by step
24V 3W Indication Light:
Radio Power Supply
Electric lock:
Set the T4 Trimmer Time to the lowest value
The electric lock is excited for 2 seconds
4138
Drwg. No.
6
70/3
PLUS
18 19
POWER SUPPLY 24V
3
4
5
6
7
8
9
10
1
2
POWER SUPPLY 24V
16 17
SINGLE-/THREE-PHASE FOR SLIDING GATE OPERATORS MEC 200
DIP-SWITCH 1:
ON: Photocells stop gate while opening,
reverse it on closing once obstacle is
removed
1
OFF: Photocells do not stop gate while
opening, reverse it on closing in
case of an obstacle
Limit switch:
DIP-SWITCH 2 and 5 (NEVER set BOTH of them to ON at the same time):
ON: Gate is not reversed while opening
OFF: Any pulse reverses the gate
2
Light ON = Open gate
Light OFF = Closed gate
Flashing (fast) 0.5s = Closing gate
Flashing (normally) 1s = Opening gate
Flashing (slowly) 2s = gate is stopped
Safety Switch
Courtesy light:
Connect a 24VAC Modular Relay
(T4 Trimmer Time from 2s to 255s)
to operate a 230V lamp
13 14
15
ON: Step by step. Stop in between
OFF: Standard operating mode
5
20
21
22
16 17