Device Description - Leister VULCAN SYSTEM Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43

Device description

7
6
5
1
Cable gland for mains connection
(mounted ex works)
2
Locking screw for frequency converter
(mounted ex works)
3
Locking screw for alarm relay
(mounted ex works)
4
Locking screw for interface
(mounted ex works)
5
Cable gland for frequency converter
(enclosed in the connection housing)
6
Cable gland for alarm relay
(enclosed in the connection housing)
Preparation
• Remove VULCAN SYSTEM from the packaging.
• Remove the connection housing cover (12) by loosening the screws (13).
• Remove warning slip,
• Remove locking screws (mounted ex works) for the frequency converter (2), alarm relay (3) and interface (4).
• Mount the enclosed cable glands for the frequency converter (5), alarm relay (6) and interface (7), if
required.
• If no interface or FU / FC (frequency converter) is used, the cable glands (5 / 7) must be removed and the locking
screws (2 / 4) mounted.
20
12
11
10
13
4
3
8
9
2
read carefully and keep at hand for consultation.
1
16
7
Cable gland for interface
(enclosed in the connection housing)
8
Flange ø 60 mm
9
Air slide
10 Potentiometer for temperature setting
11 Display
12 Connection and housing cover
13 Screws for connection housing
14 Heating element tube
15 Mounting base
16 Blower motor
15