2.4.3

Procuring the shear connectors

The shear connectors are not included in the scope of
delivery and must be provided by the user.
Recommended shear connectors:
Specifications
Qty.
Type
Anchor length
Min. substrate thickness
Min. hole depth
Embedment depth
Drill
Tightening torque
i
Shear connectors from other manufacturers may
be used, provided that they are approved by the
building authorities for use in the compression and
tension zone of the concrete. The fitting instructions
of the screw anchor manufacturer must be observed.
i
The shear connectors must penetrate the
subconcrete. The anchor length must be selected
in accordance with the floor structure over the
subconcrete:
Fig. 3:
Calculating the anchor length
L Anchor length
g
Visible thread length
t
Thickness of base plate of lifting platform column
s
Thickness of floor screed, including tiles
h Embedment depth (as specified by screw anchor manufacturer)
B Thickness of concrete (see section 2.4.2)
The embedment depth h and hole depth h+s are
specified by the screw anchor manufacturer. This
results in a minimum anchor length of L = h + s + t + g.
|
1 689 978 572
2014-06-06
Designation, value
28 items
Hilti HVA/HAS-M16x125
Refer to Fig. 3
210 mm
125 mm
125 mm
Dia. 18 mm
80 Nm
2.4.4

Laying the electrical connections

Route the supply cable to the installation location.
!
Fusing for the electrical connection must be
provided on site.
2.4.5

Routing the compressed air connection

Route the compressed air connection to the
installation location.
!
The compressed air must be directed through
a service unit located in the vicinity of the lifting
platform.
i
The service unit is not included in the scope of
delivery for the lifting platform.
Suitable service unit:
Item/component
Service unit, 0 – 10 bar, complete
(water separator, filter, pressure reducer,
lubricator)
3.

Installation

3.1

Definitions

The lifting platform components are described in the
original operating instructions.
i
The terms "left", "right", "front", and "rear" relate to
the direction of travel of the vehicle.
3.2

Hazard warnings

DANGER – Incorrectly installed lifting platform!
Risk of (fatal) injury due to the vehicle falling
or tipping during lifting or lowering and when
working on the vehicle.
Installation must only be performed by
Bosch customer service or an authorized
service outlet in accordance with these
assembly instructions.
Only install the lifting platform once
all requirements are satisfied and the
completeness of the scope of delivery has
been verified.
Part number