ELECTRONIC FILTER CLEAN REMINDER
This model air purifier has an electronic filter check to remind you when to check
and replace the HEPA-Type filters based on the air cleaner's hours of use.
When the HEPA-Type filters need to be replaced, the light will remain on until it is
RESET. You may unplug the air cleaner without interrupting the filter check.
A red LED light will illuminate when it is time to clean/check the filter.
You should periodically check the filter. Depending on operating conditions, the
filters should be replace every 6 months.
To RESET the Electronic Filter Check:
When the filter monitor light remains on, it is time to replace the HEPA-Type filters and reset the filter
monitor. With the unit powered on, insert the tip of a ball-point pen or paperclip next to the LED filter
check light and hold for approximately 5 seconds until the light turns off (Fig 5). Depending upon your
individual usage (environment and hours used), you may need to check and replace the filters more or
less frequently. If the HEPA-Type filters are replaced before the filter monitor light turns on, the filter
monitor should be reset at the same time.
These cleaning intervals are intended as guidelines only. Performance of any filter media is dependent
upon the concentration of contaminates going through the system. High concentrations of contaminates
such as dust, pet dander and smoking will reduce the useful performance of the filter.
NOTE: The HEPA-Type filters are not washable. Do not immerse in water.
REPLACING THE HEPA-TYPE FILTERS
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTER
You can purchase Honeywell replacement HEPA-type filter
store or they can be ordered directly from Home Depot at www.homedepot.com.
If you have any questions, contact Kaz Consumer Services at 1-800-447-0457.
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTER
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTER
The stage 1 particle pre-filter helps pick up large airborne particles that enter
the rear grille. This pre-filter can be periodically removed and shaken to clean
it. Alternatively, it can be rinsed by hand under warm water (Fig. 8). Let the
pre-filter air dry completely before inserting back into the unit. If you need to
replace this item, please see Consumer Relations section on the next page.