CALDAIA MURALE A GAS A CONDENSAZIONE CON BOLLITORE AD ACCUMULO IN INOX
WALL-HUNG CONDENSATION GAS BOILER WITH STAINLESS STEEL WATER-HEATER
CALDERA MURAL A GAS DE CONDENSACIÓN CON ACUMULADOR DE ACERO INOXIDABLE
CALDEIRA DE MURO À GÀS À CONDENSAÇÃO COM FERVEDOR EM INOX PARA ACUMULAÇÃO
MANUALE DI
INSTALLAZIONE E
MANUTENZIONE
AZIENDA CERTIFICATA ISO 9001
INSTALLATION
AND MAINTENANCE
MANUAL
I C
A S
E G
T O
T E N
P R
E R
N S
. U
L ' I
S I G
A K
A L
E M
N U
A S
M A
P L E
S E
T O
" U
E R
L A
O V
N
G A
A R
T E N
E G
L D
T R
U A
E N
A N
N T
" M
R E
L D
V O
U A
F A
T E N
A N
. U
" M
S R
A O
24 PLUS MB W TOP
MANUAL PARA
LA INSTALACIÓN Y
EL MANTENIMIENTO
E
S O
A R
D ' U
G N
L E
S E
U A
O N
A N
H E
T T
" M
T E
H A
D
E T
D E
U R
A N
E S
S H
" I
D E
A L
R
S E
A D
E L
E U
I L I D
R I O
T H
A B
U A
A M
U S
A L
"
L E
S O
E U
R O
G A
"
R E
S O
E U
T E
U/I
MANUAL DE
INSTALAÇÃO E
MANUTENÇÃO
"

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Lamborghini Caloreclima Futuria 24 PLUS MB W TOP U

  • Página 1 All manuals and user guides at all-guides.com AZIENDA CERTIFICATA ISO 9001 " D ' U " M T E N L ' I S I G " I I L I D P L E R I O " U "...
  • Página 2: Tabla De Contenido

    ...on an excellent choice. We thank you for the preference accorded to our products. LAMBORGHINI CALORECLIMA has been actively present in Italy and throughout the world since 1959 with a widespread network of agents and dealers to constantly guarantee the presence of our product on the market.
  • Página 3: General Instructions

    All manuals and user guides at all-guides.com GENERAL INSTRUCTIONS G This booklet constitutes an integral and essential part of the product. Read carefully the instructions contained in this booklet as they provide important directions regarding the safety of installation, use and maintenance. Preserve this booklet with care for any further consultation.
  • Página 4: Description

    All manuals and user guides at all-guides.com DESCRIPTION FUTURIA 24 PLUS MB W TOP Perfectly air-tight with respect to its surroundings, this unit is suitable for heating water to temperatures below boiling point at atmospheric pressure. Fully automatic, the FUTURIA PLUS boiler is governed by an electronic microprocessor-operated control box.
  • Página 5: Installation

    All manuals and user guides at all-guides.com INSTALLATION To be carried out by qualified personnel. The system must be installed in an area free from corrosive vapours and must comply with the legal standards in force regarding evacuation of combustion by-products. It is especially recommended that standards concerning safety, construction and flue positioning be strictly observed.
  • Página 6: Main Components

    All manuals and user guides at all-guides.com MAIN COMPONENTS LEGEND Air bleed valve Control electrode Ignition electrodes Board Transformer Fume pressure switch NTC 2 return sensor Heating circuit expansion tank 10 Circulating pump 11 Safety valve 12 Lack of water pressure switch 13 Filling cock 14 Drain cock 15 Hot water adjustment...
  • Página 7: Dimensions

    All manuals and user guides at all-guides.com DIMENSIONS mm 3/4” Ø heating delivery 3/4” Ø heating return 1/2” Ø cold water inlet 1/2” Ø hot water outlet 3/4” Ø gas inlet TECHNICAL FEATURES Expansion Thermal capacity Min. thermal capacity Hot water supply tanks Weight MODEL...
  • Página 8: Water Supply Connection

    All manuals and user guides at all-guides.com WATER SUPPLY CONNECTION Fit the assembly template up against the wall. Then fit all the piping: system delivery, system return, cold water, hot water, gas, condensation discharge and electrical power supply for the room thermostat. Once the pipes have been fitted the end fittings can be unscrewed and ordinary plugs can be inserted ready for water supply tests to be carried out.
  • Página 9: Water Circuit

    All manuals and user guides at all-guides.com WATER SUPPLY CIRCUIT LEGEND Cold water inlet Hot water outlet System delivery System return System deliver y control sensor Air bleed valve Control electrode Nozzle connection Ignition electrodes Ignition transformer Air pressure switch S y s t e m r e t u r n c o n t r o l sensor 10 Gas valve...
  • Página 10: Electrical Connections - Wiring Diagrams

    All manuals and user guides at all-guides.com ELECTRICAL CONNECTIONS - WIRING DIAGRAMS The boiler must be connected to an earthed, single-phase 230V-50 Hz mains supply by means of a three-wire cable, ensuring that connections to the LINE and NEUTRAL terminals are made correctly. A bipolar switch must be used with contacts opening to at least 3 mm.
  • Página 11: Principle Diagram

    All manuals and user guides at all-guides.com PRINCIPLE DIAGRAM LEGEND System circulating pump Return sensor Safety gas pressure switch Delivery sensor Air pressure switch Water pressure switch Amp. 13-pole connector E.A. Ignition electrode Amp. 6-pole connector E.R. Detection electrode Amp. 2-pole connector Transformer X7-X8 PC connector Main switch...
  • Página 12: Assembly Diagram

    All manuals and user guides at all-guides.com ASSEMBLY DIAGRAM LEGEND System circulating pump External sensor Safety gas pressure switch Return sensor Air pressure switch Delivery sensor Water pressure switch Ignition electrode E.A. Amp. 13-pole connector E.R. Detection electrode Amp. 6-pole connector Transformer Amp.
  • Página 13: Flue Exhaust Installation

    TYPE OF 90° ELBOW 45° ELBOW INSTALLATION FITTED FITTED CONCENTRIC FLUE 1 m. 0.5 m. EXHAUST DOUBLE FLUE PIPE 0.6 m. 0.3 m. (INTAKE/EXHAUST) ATTENTION: Use only air intake/ fumes evacuation kits produced by Lamborghini Caloreclima.
  • Página 14: Operation

    All manuals and user guides at all-guides.com OPERATION When the unit is switched on (or when it is reset), and where no heat has been requested, the system runs through the following procedure: G 5 second safety pause; G 15 seconds 3-way valve activation; G 60 seconds circulator activation;...
  • Página 15: Ignition

    All manuals and user guides at all-guides.com IGNITION SYSTEM FILLING Bring the 3-way valve into the manual position. Open the inlet valve slowly until the system reaches a working pressure (indicated on the hydrometer) of approximately 1 bar, then close it. Check that the automatic air bleed valve has its cap loosened, run the circulator to eliminate the any air in the circuit, proceeding as follows: press the ON button on the control panel (the display lights up) and activate the heating function...
  • Página 16: Operating Sequence

    All manuals and user guides at all-guides.com OPERATING SEQUENCE (display only) Button Function Button Function ON/OFF ON/OFF SWITCH SEQUENZA/STEP SELECTS PARAMETERS TO BE SUMMER/WINTER SWITCH DISPLAYED RIARMO/RESET BOILER RESET MEMO/STORE ENTERS DATA PROGRAM SELECTOR INCREASES SETTING PROG./MODE (DISPLAY) DECREASES SETTING HOT WATER ADJUSTMENT 0-60°C During boiler operation the first figure on the digital display indicates the sequence step while the...
  • Página 17: List Of Parameters Indicated By 1

    All manuals and user guides at all-guides.com LIST OF PARAMETERS INDICATED BY 1 FIGURE ON DISPLAY (Values can be adjusted by the user). To gain access to the PHASE number press the MODE button once (an indicator light to the right of the figure comes on).
  • Página 18: Data Display (Monitor System)

    All manuals and user guides at all-guides.com DATA DISPLAY (MONITOR system) Real-time data (not modifiable) regarding unit operation can be checked on the monitor. Press MODE twice (a flashing indicator light appears to the right of the 1 figure). Press STEP to display all the available PHASES.
  • Página 19: Fault Code

    All manuals and user guides at all-guides.com FAULT CODE (read-only display) The boiler control box is equipped with a microprocessor that memorises and signals any faults or shutdowns. The fault type is indicated by a code. The meaning of each code is given in the table below: figure figure Fault...
  • Página 20: Resetting

    All manuals and user guides at all-guides.com RESETTING Should there be a fault the system will shut down and flash the fault type on the display. Check for proper operating conditions (gas tap open, proper feed pressure etc.) and press RESET. Should the fault persist contact your local LAMBORGHINI ASSISTANCE CENTRE.
  • Página 21 All manuals and user guides at all-guides.com When setting has been completed press ° Phase N Parameter Range 00 = Central heating off 01 = Central heating on Central heating system 02 = Central heating on and pump in cont. mode Delivery temperature (T1) From 20°C to 90°C (minimum heating temperature)
  • Página 22 All manuals and user guides at all-guides.com When setting has been completed press ° Phase N Parameter Range Max r.p.m. in heating mode from 00 to 90 (units) Max r.p.m. in Hot water mode from 10 to 60 (x 100) Max r.p.m.
  • Página 23: Gas Valve Adjustment

    All manuals and user guides at all-guides.com GAS VALVE ADJUSTMENT The boilers leave the factory already set to their minimum and maximum output and therefore do not need to be set when installed. Should the settings need to be modified to adapt them to installation requirements it will be necessary to change fan r.p.m.
  • Página 24: Nozzle Calibration

    All manuals and user guides at all-guides.com GAS - NOZZLE CALIBRATION When leaving the factory the burners are set to operate with NATURAL GAS. For the calibration see the table below: Burner ∆P Servo Gas type Delivery Class nozzle min. max.
  • Página 25: Heating With Outdoor Sensor And Room Thermostat

    All manuals and user guides at all-guides.com HEATING WITH OUTDOOR SENSOR AND ROOM THERMOSTAT For proper use of the outdoor sensor it is compulsory to fit the room thermostat which adjusts delivery temperature T1 to ambient conditions. For each outdoor temperature reading between T4 (via parameter n° 6, adjustable between –20°C and +10°C) and 30°C there corresponds a delivery temperature T1 between the T1 temperature set by the user on the boiler (phase.
  • Página 26 All manuals and user guides at all-guides.com BRUCIATORI CALDAIE MURALI E TERRA A GAS GRUPPI TERMICI IN GHISA E IN ACCIAIO GENERATORI DI ARIA CALDA TRATTAMENTO ACQUA CONDIZIONAMENTO Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più...
  • Página 27 All manuals and user guides at all-guides.com AZIENDA CERTIFICATA ISO 9001 CALDAIA MURALE A GAS ALTO RENDIMENTO - MODULANTE MANUALE PER L‘UTENTE Alla cortese attenzione del sig. INSTALLATORE: Consegnare il presente manuale d’uso all’UTENTE WALL-HUNG GAS BOILER FOR HIGH EFFICIENCY - MODULATING USER MANUAL For the attention of the INSTALLATION TECHNICIAN: make sure that this manual is handed over to the USER...
  • Página 28 The “LAMBORGHINI SERVICE” after-sales centres are at your disposal to ensure QUALIFIED MAINTENANCE and PROMPT SERVICE. LAMBORGHINI CALORECLIMA For the installation and positioning of the boiler CAREFULLY OBSERVE THE LOCAL REGULATIONS IN FORCE...
  • Página 29: General Instructions

    All manuals and user guides at all-guides.com GENERAL INSTRUCTIONS G This booklet constitutes an integral and essential part of the product and should be preserved for any further consultation. Read carefully the instructions contained in this booklet as they provide important directions regarding the operation of the appliance, allowing a great saving in its use and maintenance.
  • Página 30: Instructions For The Use

    All manuals and user guides at all-guides.com INSTRUCTIONS FOR THE USE G In case of breakdown and/or malfunctioning of the appliance, disconnect it avoiding any attempt of repair or direct intervention. Call exclusively professionally qualified personnel. Any repair must be carried out by an after-sale service centre “LAMBORGHINI SERVICE” authorised by the manufacturing firm, and using original replacements exclusively.
  • Página 31: Checks And Maintenance

    All manuals and user guides at all-guides.com CHECKS AND MAINTENANCE G Before starting up the boiler ask qualified personnel “LAMBORGHINI SERVICE” to check: a) that the data on the information plate corresponds to that required by the gas, electrical and water supply networks;...
  • Página 32 All manuals and user guides at all-guides.com DIMENSIONS mm CONTROL PANEL Main switch “STORE” key to save data SUMMER/WINTER selector “+” key to increase settings Boiler “RESET” key “-” key to reduce settings Data display 10 Hydrometer “MODE” key to select the program 11 Hot water adjustment “STEP”...
  • Página 33: Adjustments

    All manuals and user guides at all-guides.com ADJUSTMENTS Button Function Button Function ON/OFF SWITCH SELECTS PARAMETERS TO BE ON/OFF SEQUENZA/STEP SUMMER/WINTER SWITCH DISPLAYED BOILER RESET ENTERS DATA RIARMO/RESET MEMO/STORE PROG./MODE P R O G R A M S E L E C T O R INCREASES SETTING (DISPLAY) DECREASES SETTING...
  • Página 34: Fault Code

    All manuals and user guides at all-guides.com FAULT CODE The boiler control box is equipped with a microprocessor that memorises and signals any faults or shutdowns. The fault type is indicated by a flashing code. The meaning of each code is given in the table below: figure figure Fault...
  • Página 35: Resetting

    All manuals and user guides at all-guides.com RESETTING Should there be a fault the system will shut down and flash the fault type on the display. Check for proper operating conditions (gas tap open, proper feed pressure etc.) and press RESET. Should the fault persist contact your local LAMBORGHINI ASSISTANCE CENTRE.
  • Página 36 All manuals and user guides at all-guides.com BRUCIATORI CALDAIE MURALI E TERRA A GAS GRUPPI TERMICI IN GHISA E IN ACCIAIO GENERATORI DI ARIA CALDA TRATTAMENTO ACQUA CONDIZIONAMENTO LAMBORGHINI CALOR S.p.A. VIA STATALE, 342 44040 DOSSO (FERRARA) ITALIA TEL. ITALIA 0532/359811 - EXPORT 0532/359913 FAX ITALIA 0532/359952 - EXPORT 0532/359947 Cod.