IGNITION

SYSTEM FILLING
Bring the 3-way valve into the manual position. Open the inlet valve slowly until the system reaches a
working pressure (indicated on the hydrometer) of approximately 1 bar, then close it.
Check that the automatic air bleed valve has its cap loosened, run the circulator to eliminate the any air
in the circuit, proceeding as follows:
press the ON button on the control panel (the display lights up) and activate the heating function
(Winter/Summer switch set to in Winter) to start the circulator. Press the OFF button to stop the circulator;
repeat the procedure until all the air has been vented.
Reset the 3-way valve to the "automatic" position.
IGNITION
Open the gas tap, press the ON button. The burner will ignite automatically (the heating and hot water
functions are set by the manufacturers).
Should the unit fail to ignite there will be another 2 ignition attempts after which there will be a shutdown
(the display will flash 2 - 02). Press RESET: if the unit still fails to ignite contact the technical assistance
service.

CONTROL PANEL

Button
Function
ON/OFF SWITCH
ON/OFF
SUMMER/WINTER SWITCH
RIARMO/RESET
BOILER RESET
PROG./MODE
PROGRAM SELECTOR
(DISPLAY)
ADJUSTING HEATING TEMPERATURE
1) Press (MODE). An indicator light on the left-hand display comes on.
2) Press (STEP) to phase 4.
3) Press the (+) (-) buttons to modify the hot water temperature.
4) Press (STORE) to memorise the data.
5) Press (MODE) twice to enter the new temperature setting.
All manuals and user guides at all-guides.com
Button
Function
SELECTS PARAMETERS TO BE
SEQUENZA/STEP
DISPLAYED
MEMO/STORE
ENTERS DATA
+
INCREASES SETTING
-
DECREASES SETTING
HOT WATER ADJUSTMENT
0-60°C