To avoid all risk, if the power cable becomes damaged,
it must only be replaced by the manufacturer,
by an authorised service centre, or by a qualified
electrician.
Adaptation to various types of gas (Fig. 5)
Should the appliance be pre-set for a different type of
gas than that available, proceed as follows:
• replace the injectors (Fig. 5) with the corresponding
type of gas to be used (see table "Uses
characteristics").
• to adjust to the minimum, use a screwdriver on the
screw placed on the tap (Fig. 6) after turning the tap
to its minimum position. For LPG (butane/propane)
screw tight
USER CHARACTERISTICS
GAS BURNERS
FEED
TYPE
PRESSURE mbar
NORM.
natural gas
G20
20
liquefied gas
G30/G31 28-30/37
Fig. 6
BURNER
Ø INJECTORS
1/100 mm
fast
129
auxiliary
77
wok 3
141
fast
87
auxiliary
50
wok 3
94
wok C3 only
THERMAL CAPACITY
NOMINAL
CONSUMPTION
W
3000
286
1000
95
3500
333
3000
218
1000
73
3500
254
GB
Fig. 5
7