FRONT PANEL

1
Display
Function /
2
Range
Switch
VΩmA
3
Terminal
COM
4
Terminal
10A
5
Terminal
HOLD
6
Button
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
3 1/2 digital 15 mm height, 7 sections LED display
Used to select the desired function or range as well as to turn on or off the
meter. To preserve battery life, set this switch to OFF position when the meter is
not in use.
Plug-in connector for the red test lead for most measurements.
Plug-in connector for the black test lead for all measurements.
Plug-in connector for red test lead for current 200 mA to 10 A measurements.
Press the HOLD button. The LED will hold the last reading measured and
display the
H
symbol. When the button is released, the instrument will return to
normal mode.