INSTRUCTIONS
Notices before operation:
1. Plug the instrument in, check the 9V battery, if it is low, the symbol
battery replacement; otherwise follow the steps below.
2. The
besides the probe jack indicates that the input voltage or current should not exceed the
specified limits to protect the internal circuit.
3. Before measurement, turn the function / range switch to the desired range.
Direct current voltage measurement
Insert the red probe into the " VΩmA " jack and the black one
into the " COM " jack.
Turn the function / range switch to the V- range and connect the
probe to the power supply or load to be measured. The polarity
touched by the red probe will be shown on the display.
Notice
If you do not know the measured voltage range in advance, set
the function / range switch to the maximum range, and then
gradually turn to smaller ranges until satisfactory resolution.
If the display shows "1" this indicates an over-range
measurement, and the switch should be set to a higher range.
Do not input a voltage of more than 600V, it is capable of
indicating a higher voltage, but with the risk of damaging the
inside circuit.
When taking the measurement of high voltage, pay special
attention to avoid an electric shock.
Direct current measurement
Place the black probe into the " COM " jack, for current to be
measured not exceeding 200mA, put the red one into the " VΩmA "
jack. For current to be measured between 200mA and 10A, insert
the red probe into the " 10A " jack.
Set the function / range switch to desired Ampere range and connect
the probe in series with the load to be measured. The current value
and the polarity connected to the red probe will be shown on the
display.
If you do not know the measured voltage range In advance, set the
function/range switch to the maximum range, and then graduaIly turn
to smaller ranges until satisfactory resolution.
If the display shows " 1 " this indicates an over-range measurement,
and the switch should be set for a higher range.
The symbol "
current is 200mA or 10A, depending on the inserted jack.
Over current will blow the fuse.
BGS technic KG