Technical Data - BGS technic 63402 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

MAINTENANCE
Before removing the rear cover, disconnect the probe from the circuit to be measured.
To protect the internal circuit, replace the fuse with one of the same specification.
Don't use the instrument until the rear cover is placed back and the screws are tightened.
Clean the housing of instrument only with a wet rag dripped with little detergent but never chemical
solution. In case of any abnormality, stop using it and sent it for maintenance.

TECHNICAL DATA

Accuracy: +% of reading 5 digits, one year warranty.
Max. Voltage between input and the ground:CAT III 600V / Protection Type: IP20 / Protection Class: II
Fuse: F1 250mA / 600V F2 10A / 600V
Over-range indication: "1" (input higher than range) Polarity display: " - " for negative polarity
Operating temperature: 0°C to 40°C
Ambient temperature: 18°C to 28°C
Low voltage indication: " " on the display
Dimension: about 138 mm x 69 mm x 31 mm
DC Voltage
Range
200 mV
2 V
20 V
200 V
600 V
Overload protection: 200mV range: 250V DC or RMS; the rest ranges: 600 V DC or RMS
AC Voltage
Range
200 V
600 V
Overload protection: 600V DC or RMS, Frequency range: 40Hz to 400Hz
Display: Average (effective value of sinusoid)
DC Current
Range
20 µA
200 µA
2 mA
20 mA
200 mA
10 A
Overload protection: F1: 250mA / 600V - Fuse F2: 10A / 600V
Resistor
Range
200 Ω
2 KΩ
20 KΩ
200 KΩ
2 MΩ
Maximum open circuit voltage: 3.2V, Overload protection: 250V DC or RMS
Diode
Range
The approx. forward voltage drop of the diode will be displayed.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Power: 9V NEDA 1604/1604A, IEC 6F22/6LR61
Storage temperature: -10°C to 50°C
Ambient humidity: 80%
Maximum display value: 1999
Weight: 170g
Resolution
100 µV
1 mV
10 mV
100 mV
1 V
Resolution
100 mV
1 V
Resolution
0.01 µA
0.1 µA
1 µA
10 µA
100 µA
10 mA
Resolution
0.1 Ω
0.001 KΩ
0.01 KΩ
0.1 KΩ
0.001 MΩ
Description
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
Accuracy
±(0.5% +3)
±(0.8% +5)
Accuracy
±(1.2% +10)
Accuracy
±(1.0% +3)
±(3.0% +10)
Accuracy
±(0.8% +2)
±(1.0% +5)
www.bgstechnic.com