Frequency
Set the selector switch [9] measuring range to
"HZ/%".
Plug the black measuring lead into the COM jack [5].
Plug the red measuring lead into the V/Ω input
jack [6].
Connect the measuring leads to the circuit being
tested.
The measurement result is output at the display [1].
3
Frequency
Measuring
Resolution
range
5 Hz
0.001 Hz
50 Hz
0.01 Hz
500 Hz
0.1 Hz
5 kHz
1 Hz
50 kHZ
10 Hz
500 kHz
100 Hz
1 MHz
1 MHz
Sensitivity: 5 V
RMS
Max. input voltage: 120 V

Engine speed

Set the selector switch [9] measuring range to "
".
Set the number of cylinders using the cylinder-
selection (CYL) button [4].
Plug the black measuring lead into the COM jack [5].
Plug the red measuring lead into the V/Ω input
jack [6].
Connect the black measuring lead to the vehicle
ground.
Connect the red measuring lead to the negative
terminal of the ignition coil.
The measurement result multiplied by 10 is
3
displayed.
Engine speed
Cylinder
Resolution
4 CYL
5 CYL
1 rpm
6 CYL
8 CYL
Sensitivity: 5 V
RMS
Max. input voltage: 120 V
20
Accuracy
± 1.0 % + 4 d
RMS
Accuracy
± 3.0 % + 5 digits
RMS
Dwell angle (ignition point)
Set the selector switch [9] measuring range to
"Dwel 
".
Plug the black measuring lead into the COM jack [5].
Plug the red measuring lead into the V/Ω input
jack [6].
Connect the black measuring lead to the vehicle
ground.
Connect the red measuring lead to the negative
terminal of the ignition coil.
Dwell angle
Cylinder Measuring
range
4 CYL
0–90
5 CYL
0–72
6 CYL
0–60
8 CYL
0–45

Duty cycle

Set the selector switch [9] measuring range to
"HZ/%".
Press the HZ/% button [12] to set to "%".
Plug the black measuring lead into the COM jack [5].
Plug the red measuring lead into the V/Ω input
jack [6].
Connect the measuring leads to the circuit being
tested.
The measurement result is output at the display [1].
3
Duty cycle
Measuring
Resolution
range
0–100 %
0.1 %
Sensitivity: 5 V
RMS
Max. input voltage: 120 V

Capacitance measurement

Set the selector switch [9] measuring range to "F".
Press zero balance (REL) [2] to zero.
Plug the black measuring lead into the COM jack
[5].
Plug the red measuring lead into the V/Ω input
jack [6].
Connect the measuring leads to the circuit being
tested.
The measurement result is output at the display [1].
3
Max. input voltage: 36 V
Resolution Accuracy
0.1
± 3.0 % + 5 d
Accuracy
± 3.0 % + 5 d
RMS
RMS

Publicidad