Item no.
DC voltage measurement
AC voltage measurement
DC current measurement
Resistance measurement
Diode test
Continuity test
Temperature measurement
Speed measurement
Dwell angle measurement
Duty cycle measurement
Frequency measurement
Fuses
Max. operating altitude
Figure height
Display
Polarity indication
Overflow display
Sample rate
Battery state
Power supply
Operating temperature
Storage temperature
Dimensions
Weight
Automatic switch-off
16

Technical Data

0715 53 440
0...120 V
0...50 V
0...400 mA
4...20 A
0...4 MΩ
4...40 MΩ
Forward current: approx. 25 μA
0...45 Ω
-20...400 °C
400...1000 °C
500...10,000 rpm
0...90°
0...100 %
0...1 MHz
400 mA self-resetting (maintenance-free), F 20 A
2000 m above seal level
26 mm
4 digits (max. 9999)
automatic
"1" is displayed
approx. 0.4 s
Battery symbol is displayed
1 × 9 volt battery (6F22)
0 °C to 40 °C RH < 80 %
-10 °C to 50 °C RH < 80 %
180 × 84 × 55 mm
335 g including battery
After approx. 15 min.
Accuracy
± 0.5 % + 4 d
± 1.2 % + 8 d
± 1 % + 5 d
± 1.2 % + 10 d
± 1 % + 3 d
± 2 % + 3 d
± 1 % + 5 °C
± 1.5 % + 15 °C
± 3 % + 5 d
± 3 % + 5 d
± 3 % + 5 d
± 1 % + 4 d

Publicidad