Troubleshooting (cont.)
Valve Troubleshooting Table
Symptoms
1.
Maximum blend
temperature too hot or
too cold.
2.
Continuous flow.
3.
Handshower does not
work.
4.
Only cold water flows
from the outlets.
Fluctuating or reduced
5.
flow rate. Valve is
functioning properly.
6. Blend temperature drift or
temperature cycling.
1093174-5-B
Probable Cause
A. Incorrect maximum temperature
setting.
B. Inlet/outlet fittings may be
blocked.
C. If the above recommended
action does not correct the
symptom, the interface or valve
requires servicing.
A. System will not switch off.
A. Handshower is not enabled.
A. Hot water supply is either not
turned on or not connected to
the valve inlet.
B. Hot water inlet is blocked.
C. If none of the recommended
actions for the above issues
correct the symptom, the valve
requires servicing.
A. Inlet/outlet fittings may be
blocked.
B. Water outlet pressure is low.
C. Fluctuating flow.
D. If none of the recommended
actions for the above issues
correct the symptom, the valve
requires servicing.
A. Fluctuating water temperature.
B. Hot water supply temperature
fluctuation.
C. Pressure difference greater than
5 psi (34.5 kPa) between the hot
and cold supply lines.
Recommended Action
A. Refer to the "Set the Maximum
Temperature" section in the Digital
Interface User Guide.
B. Check the inlets and outlets for
blockage or debris. Clean the inlet
screens. Refer to the "Clean the
Inlet Screens" section in the Valve
Homeowners Guide.
C. Contact your Kohler Co.
Authorized Service Representative.
A. Turn off the water and power
supply and contact your Kohler Co.
Authorized Service Representative.
A. Enable the handshower option in
the settings menu. Refer to the
Digital Interface User Guide.
A. Check the hot water supply is
turned on and connected to the
valve inlet.
B. Check the hot water inlet screen for
blockage. Clean or replace the inlet
screen. Refer to the Valve
Homeowners Guide.
C. Contact your Kohler Co.
Authorized Service Representative.
A. Check the inlets and outlets for
blockage or debris. Clean the inlet
screens. Refer to the "Clean the
Inlet Screens" section in the Valve
Homeowners Guide.
B. Check that the flow rate is at or
above the minimum rate required.
Refer to "Specifications" section in
the Valve Homeowners Guide.
C. Verify that the dynamic inlet
pressures are within specifications.
Refer to "Specifications" section in
the Valve Homeowners Guide.
D. Contact your Kohler Co.
Authorized Service Representative.
A. Check the inlet temperature
differentials and verify they are
sufficient. Refer to "Specifications"
section in the Valve Homeowners
Guide.
B. Check and make adjustments as
needed.
C. Install pressure regulators to bring
the supplies within 5 psi (34.5 kPa)
of each other.
8