Dimplex LA12MI Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SETTING UP THE SPECIAL FUNCTIONS
SETTING UP THE SPECIAL FUNCTIONS
• After initial installation, you can manually adjust the settings. The initial setting remains active until the user changes it.
• The remote control can be used for multiple installations. Some functions may not be applicable to your unit.
• Ensure the operation LED is in OFF condition before setting.
Operation
Mode
Timer display
SETTING
STATUS
SET
CHECK
SELECT
CANCEL
SET
CHECK
1. Press
and
2. Press
or
SELECT
3. Press
to enter the function.
4. Press
or
SET
5. Press
to confi rm.
Operation Mode/
Function *
Actual Operation Description
TANK
SOLAR
HEAT
HEAT
TANK
BOOSTER
• Do not use the system during sterilization to prevent scalding or overheat during shower.
• The sterilization function fi eld settings must be confi gured by the authorized dealer according to local laws and regulation.
8
Day display
HEAT
TANK
QUIET
HEATER
FORCE
OPERATION
SEARCH
SELECT FUNCTIONS AND SET YOUR DESIRED TIMER
simultaneously for 5 seconds to enter special setting mode. "SETTING" and "STATUS" indicator is ON.
to browse functions.
to enable YES or disable NO function, or set your desired day and time.
External Thermo Controller (YES / NO)
To set external thermo controller connection.
Tank Connection (YES / NO)
To set tank connection.
Solar Priority (YES / NO) (Not Applicable)
To choose the solar use for water tank heat up.
Heating Priority (YES / NO)
To choose the heat pump only use for Heating side during HEAT + TANK mode.
Heating Heat-up Interval Set
To set timer for Heating during HEAT + TANK mode (0.5hour ~ 10hours).
Tank Heat-up Interval Set
To set timer for Tank during HEAT + TANK mode (5minutes ~ 1hour 35minutes).
Booster Heater Delay Time Set
To set delay timer for booster heater to ON if tank temperature is not reached (20minutes ~ 1hour
35minutes).
Sterilization (YES / NO)
To set sterilization, if required.
Sterilization Day & Time Set
To set timer for sterilization (only once a week).
Sterilization Temperature Set
To set temperature for sterilization function (40°C ~ 75°C).
Sterilization Continue Time
To set timer to maintain heating temperature in order to complete the sterilization function
(5minutes ~ 1hour).
YES / NO / Temperature display
TIMER
OUTDOOR
WATER OUTLET
Functions*
SETTING / STATUS indicator
ACTUAL
HEATER
Actual Operation
BOOSTER
SETTING
STATUS
PUMPDW