PROBLEM
Screen does not work after
connecting power supply
Controller does not control fixtures
Controller does not show
temperature after connecting with
temperature probe
Fixture status is different from the
power set by controller
When connecting several fixtures,
the first several fixtures work
normally, while the following
fixtures function abnormally
CUSTOMIZING YOUR LIGHTING LAYOUT
Fixtures fail to turn off
See pages 8-23 for data link cable guides that show you how to customize your lighting setup
with the same or multiple lighting technologies within the same environment.
LED Fixtures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
HID Fixtures
Phantom with USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Core 2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Multiple Lighting Technologies
LED + Dual CMH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
LED + DE HPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Dual Zone DE HPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
DE HPS + Dual CMH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
DE HPS + DE MH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
TROUBLESHOOTING
CHECK
Check if the power supply/
adapter/controller works
normally
Check if the signal cable is
connected well and is fully
inserted/locked; check pin
condition
Check if the temperature
probe is inserted fully
Check if the fixture is under
sunrise and sunset mode or
if the temperature is under
temperature protection mode
Check if the signal cable is
connected well, or if the
pins of the connectors are
damaged, or the LED status
on fixtures
Check fixture quantity per
zone. Too many fixtures will
cause residual voltage in the
cable system.
SOLUTIONS
Unplug DC connector from the
controller momentarily then
reconnect taking care to ensure
the connector is fully inserted
and tightened
Reconnect the signal cable and
go fixture by fixture to identify
communication loss point
Disconnect and reconnect the
temperature probe
Adjust the time of sunrise and
sunset or reset the temperature
limits
Reconnect the signal cable, or
replace any damaged fixture
Reduce number of fixtures per
zone