Warning Regarding Wall Mount; Basic Operations - VESTEL EVC02 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

To minimize fire or electric shock risk to a
minimum, do not use this appliance with an
extension cord. If the electric cord or electric
vehicle cord is damaged, in order to prevent
any danger, the cord must be replaced by the
manufacturer, its service agent or other qualified
persons.

WARNING REGARDING WALL MOUNT

Prior to mounting your charging station on the
wall, read these instructions.
Do not mount your charging station to the ceiling
or an inclined wall.
Use the wall mounting screws and other
accessories specified.
This appliance is classified as indoor and outdoor
mount compatible. If the device is mounted
outside the building, the hardware that will be
used to connect the conductors to the appliance
shall be compatible with outdoor use and the
appliance shall be mounted preserving the IP
rate of the appliance.

BASIC OPERATIONS

The appliances include mobile connection and RFID
card readers. Mobile connection is used to connect
the charging station to an OCPP central system.
RFID cards are provide to authorize the user to
use the system and is issued by Charging Station
Operator.
Button Lamp Colour
Display
Ready : Solid Blue
Charging : Blinking
Malfunction : Solid Red
Until central system connection
is established : Blinking
Reserve Station : Blinking
After scanning the RFID card on the reader on the
station, the station checks through OCCP central
system whether the card is authorized. During this
period LED will rapidly blink in blue colour.
Blue
Red
Blue - Red
English - 3 -
- If the card is authorized for a charge, the LED
will blink slowly in blue indicating that the charge is
initiated.
- If the card is not authorized for charging or there
is an issue at the station preventing starting the
charge, such as a reservation etc., LED will blink in
red to notify the user.
.
Charging cord will be locked when charge is initiated
and will be unlocked when charging process is
completed. The charging process may be ended as
specified below:
a) Scanning the RFID card on the RFID symbol on
the charging station. (The RFID card that is used to
initiate charging shall be used)
b) When the charging cord is removed from the
vehicle,
c) With the messages sent from the server
(unlocking the socket, remote stopping etc.)
This station is designed to charge rechargeable
hybrid vehicles with Type 2 charging cord with a
battery.
When the device is first booted, the LED button light
will blink in red colour until the server connection is
established, when the connection is established, the
light will turn to solid blue colour.
Insert the charger plug to the electric vehicle and
then the charging station. To initiate the charge,
charging station requires an authorized RFID card.
If it blinks in red after the charging cord is connected
to the vehicle and the station, this indicates that your
vehicle requires ventilation based on the battery
type. This charging station is not suitable to charge
the vehicles that require ventilation.
If the LED is solid red, please check the
Troubleshooting section and do not connect and
charging plug to the station.
Invalid card
or
Reserved station

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Evc02-ac22gr-6Evc02-ac11gr-6Evc02-ac22ur-6Evc02-ac11ur-6

Tabla de contenido