Notes and instructions with the following symbols require particular attention:
Any non-observance of these instructions involves the danger of bodily harm to people and/or
damage to property.
Any non-observance of this instruction bears the risk of an electrical shock which may cause
damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be
informed immediately, at the latest within 8 days after the date of purchase.
2. Functioning
The Brio 2000 M electronic pump control allows the automation of any type of pressure pump that is capable of
generating a pressure of more than 1.5 bar. Automation means that the liquid being discharged can be used just
as though it would come out of the water mains and: by simply opening or closing water taps or other consumers.
The Brio 2000 M provides an additional benefit in that it prevents the pump from damage by dry running, since the
pump will cut out in the absence of water.
As soon as the connection to electrical mains is established, the Brio 2000 M will activate the pump for
approximately 15 seconds. The pump will cut in automatically as soon as a consumer is opened and causes the
pressure within the pipe system to drop to the cut-in pressure of the Brio 2000 M.
In contrast to pumps that are equipped with pressure vessels such as, for instance, domestic booster systems,
the automatic cut-out of the pump will not occur upon the reaching of a specific cut-out pressure, but rather by the
reduction of the flow rate down to minimum value as a result of the closing of consumers. In this process, the Brio
2000 M electronic pump control will delay cutting-out by 7 to 15 seconds. This method will decrease the cut-in/cut-
out frequency of the pump at low flow rates and thus contribute to a sparing operation of the unit. This feature is
also activated in the case of the pumps dry-running and thus protects the device efficiently from damage which
may be caused by operation in the absence of water.
The cut-in pressure and the pressure inside the pipe system can be checked using the built-in pressure gauge.
When using the Brio 2000 M, the liquids to be discharged must not contain any solids since this may entail
functional disturbances. If this cannot be excluded, please use an efficient prefilter at the intake area of the pump.
The unit is not suited to discharge saltwater, faeces, inflammable, etching, explosive or other
hazardous liquids. Please observe the max. and min. temperatures of the liquids to be
discharged stated in the technical data.
3. Technical Data
Model
Mains voltage / frequency
Max. current strength for connection socket
Protection type
Intake port
Outlet port
Max. operating pressure
Cut-in pressure setting range
Preset default cut-in pressure
Max. size of the solids being pumped
Min. fluid temperature
Max. fluid temperature (T
)
max
Length of connection cable
Cable type
Weight (net)
Dimensions (L x D x H)
Item no.
4. Scope of delivery
The scope of the delivery of this product includes:
One electronic pump control with a connection cord, one double nipple, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation" and "How to order spare parts").
Brio 2000 M
230 V~ 50 Hz
12 A
IP65
(1 "), female, rotating
30.93 mm
(1 "), male
33.25 mm
10 bar
1.0 - 3.5 bar
1.5 bar
0 mm
2 °C
55 °C
1.3 m
H05RN-F
0.75 kg
10 x 10 x 19.5 cm
30241
2
9