Operating Instructions Enabling Switch ZXE
Version
ZXE-091336
Version
ZXE-104833
ZXE-120348
Version
Tab terminals for the working contacts
ZXE-111276
C2
Fig. 3: Dimension drawing, ZXE enabling switch
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49 711 7597-0 Fax +49 711 753316 info@euchner.de www.euchner.de
27,5
M22 x 1
Screw terminals for the working contacts
43,5
14
24,8
< 27,5>
ZXE-104833
M22 x 1
20
NO1
C1
NO2
Screw terminals for the working contacts
25,5
1,2
33,5
C1
NO1
NO2
25
< 27,5>
M22 x 1
20
NO 1
C1
NO 2
C2
20,5
Front panel cut-out
ZXE-120348
20
C2
NC2
C2
NO1
C1
20,5
Front panel cut-out
20
EC declaration of conformity
The manufacturer named below herewith declares
that the product fulfills the provisions of the
directive(s) listed below and that the related standards
have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen, Germany
Directives and standards applied:
Three-position enabling switch
f
- Machinery directive 2006/42/EC
- EMC directive 2004/108/EC
- EN 60947-5-8:2006
Leinfelden, March 2013
Dipl.-Ing. Stefan Euchner
Director
Duc Binh Nguyen
Authorized representative empowered to draw up
documentation
The signed EC declaration of conformity is included
with the product.
Technical data
Parameter
Value
Housing material
Polyamide, color black
Protective cap material
CR, color black
Weight
Approx. 30 g
Degree of protection a
front IP65
ccording to IEC 60529
connections IP00
Mechanical life min.
Position 1-2-1
1x10
cycles
5
Position 1-2-3-1
1x10
cycles
5
Ambient temperature
-5 ... +60 °C
Degree of contamination
3 (industrial)
(external, acc. to EN 60947-1)
Installation position
Any
Impact strength
> 100 N
Switching elements
ZXE-091336/ZXE-104833/
ZXE-111276
2 NO contacts
ZXE-120348
1 NO contact + 1 NC contact
Connection
Screw terminal 4-pin/
tab connector, 4-pin
Tightening torque, max.,
0.15 Nm
of the screws
Conductor diameter
single-conductor 0.3 - 1.4 mm,
AWG 22 - 16
Conductor nominal
Single-conductor 1.5 mm²,
cross-section
flexible wire 1 mm², AWG 16
Insulation stripping length
5 mm
Rated impulse
U
= 1.5 kV
imp
withstand voltage
Rated insulation voltage
U
= 30 V
i
Rated short-circuit current
100 A
Utilization category
DC-13 0.1 A 24 V
acc. to EN 60947-5-2
Breaking capacity max.
250 mW
Switching current max.
100 mA
Switching current min.
5 mA
External fuse
100 mA medium slow-blow
U (+LA) / U (+LB)
Reliability figures acc. to EN ISO 13849-1
B
1 x 10
5
10d