Step 1. If using the largest
tubing size recommended for
your pump, trim the tubing
adapter using a hacksaw at
the location indicated.
Step 2. For item #52321
Connect the adapter to the
pump, and connect the tubing
to the outlet of the adapter.
For item #52325 Connect
the tubing to the outlet of the
pump.
NOTE: Tubing is not included.
Step 3. Place the pump
inside the Pump barrier bag.
Pull the drawstring until the
Pump barrier bag is fully
closed around the tubing and
power cord. Tie a knot in the
drawstring.
Step 4. Place the pump into
the water and connect to a
properly grounded electrical
outlet.
PUMP PERFORMANCE
52325
Pump Specifications
Max Flow Rate
1200 GPH at 0 ft. height
Max Pumping Height
16 ft. (0 GPH)
Power Consumption
75 watts / 0.85 amps
Cut ring
Adapter before cut
3
52321
Pump Specifications
Max Flow Rate
2250 GPH at 0 ft. height
Max Pumping Height
17 ft. (0 GPH)
Power Consumption
105 watts / 1.3 amps
1
Adapter after cut
2
4
GFCI
Outlet
3