Specifications; Reference Conditions; Operating Conditions - PCE PAC 20 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4/ SPECIFICATIONS

Ranges Input/output ratio
1000 A
1 mV/A
4.1/ RÉFERENCE CONDITIONS
- Temperature: 18...28°C
- Humidity rate: 20...75% RH
- Battery voltage: 9 V ± 0.1 V
- Position of conductor: centred on the markings of the clamp
- Magnetic field: earth's DC field
- Absence of external AC magnetic field
- Absence of electric field
- Measurement for a DC current or an AC sinusoidal current ≤ 65 Hz
- Impedance of the measurement instrument: ≥ 1 MΩ and ≤ 100 pF

4.2/ OPERATING CONDITIONS

The instrument must be used in the following conditions to satisfy
the safety of the user and the metrological performance:
- Use indoors
- Altitude: ≤ 2000 m
- Transportation altitude: ≤ 12 000 m
Storage
Stockage
% RH
90
80
70
60
50
40
30
20
10
0
-50
-40
-30
-20
-10
Measurement extent
A AC rms
A peak max
0.5...1000
0.5...1400
Use
Utilisation
0
10
20
30
40
50
60
température en °C
Temperature
12
A DC
0.5...1400
Reference
Réference
°C
70
80
90

Publicidad

Tabla de contenido
loading

Tabla de contenido