Valve terminal/Solenoid valve
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This product is recognized by UL. Representative samples
of this component have been evaluated by UL and meet
applicable UL requirements.
UL approval information
Product category code
YIOZ2 (USA),
YIOZ8 (Canada)
File number
MH19482
Considered standards
UL 429,
C22.2 No.139
UL mark
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fitting and commissioning is to be carried out by quali-
fied personnel only in accordance with the operating
instructions.
Such qualified personnel must have several years of
training and experience in installing and commissioning
electrical and pneumatic industrial control systems.
• Please observe the applicable safety requirements
and standards.
Conversion or extension of the product with modules,
for which the Recognized Component Mark of UL does
not apply, will lead to loss of the UL certification.
• Contact Festo if you require information on UL-certi-
fied modules.
Only for connection to a NEC Class 2 supply
Raccorder Uniquement a un circuit de Classe 2
This device is intended to be used with a Class 2 power
source or Class 2 transformer in accordance with UL1310
or UL1585.
As an alternative a LV/C (Limited Voltage/Current) power
source with one of the following properties can be used:
This device shall be used with a suitable isolating source
such that the maximum open circuit voltage potential
available to the product is not more than 24 V DC and the
current is limited to a value not exceeding 8 A measured
after 1 minute of operation.
This device shall be used with a suitable isolating source
in conjunction with a fuse in accordance with UL248. The
fuse shall be rated max. 4 A and be installed in the
24 V DC power supply to the device in order to limit the
available current.
Note that, when more than one power supply or isolating
device is used, connection in parallel is not permitted.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Extracts )* from the UL report:
Technical data
VTOC
Electrical
24 V DC,
ratings
max. 5.3 W (2 valves)
to 63.4 W (24 valves)
Max. operating
8 bar (116 psi)
pressure diffe-
rential
Max. body
8 bar (116 psi)
pressure
Ambient
-5 to +50 °C
temperature
(23°F to 122 °F)
Note
range
Fluid temperature
-5 to +50 °C
range
(23°F to 122 °F)
Fluids
Air, inert gases
Conditions of acceptability:
– The devices are intended to be provided with an end-
use enclosure to protect the plastic valve bodies from
impact.
– The devices are intended for factory wiring only.
– The fluid connections are not standardized. The sui-
tability with regard to leakage and mechanical strength
shall be evaluated in the end use.
– The suitability of any mating fluid connector shall be
determined in the end product.
)* taken over essentially without important changes
en
VOVC
22 V DC,
2.64 W (two coils
energized)