INSTALLATION
2.a
PUMP MODULE
The power supply must come from a different network than the air conditioner supply.
Disconnect the power supply before installation.
The power cable must be connected by a qualified professional complying with the standards in force
in the country.
Use only the cable 3 drivers supplied with a protection 10 A on the line.
This power supply cable must be grounded.
(standard NFC 15100 lays down the installation of a high sensitivity differential circuit breaker for
dwelling units (30 m A))
In case of doubt and for any interventions concerning electrical connection, it is preferable to call a
qualified professional.
SICCOM would not be held responsible for possible damages caused by a improper installation
If the power cable is damaged, it should be replaced by the manufacturer, its after-sales service or
similarly qualified persons in order to avoid any danger.
Installation of the pump module.
The pump module may be installed in the air conditioner, in a chute (see diagram, opposite) or in the
false ceiling. A space must be left around the pump module for it to cool in the event of prolonged
operation. The pump module should not be covered (no insulation, no expanding foam, etc.). The
discharge tube must be 6 x 9 mm in diameter. Use the hose clamp (supplied) to securely fasten the
discharge hose to the pump. Make sure to observe the flow direction indicated by the arrow on
the pump module.
2.b
DETECTION MODULE.
The flexible elbow (supplied) allows connection of the detection module to the air conditioner tray.
Suction is via the 1.50-meter flexible hose having a diameter of 6 x 9 mm (not supplied). Use the two
hose clamps (provided) to securely fasten the flexible hose to the detection and pump modules
Installation of the detection module.
For the ECO FLOWATCH ®, the detection module must be installed and fastened in a horizontal
position with the velcro adhesive support (supplied).
The outlet discharge tube of the pump module must always be higher than the detection
module. In other case, it is necessary to connect the outlet discharge tube to another tube of a
higher diameter in order to prevent siphoning. Detailed information is available from your nearest
wholesaler.
OPERATION
Check that the maximum water level in the
condensate tray is higher than the cover level in
the detection unit, to prevent the condensate tray
overflowing before the alarm activates.
Before finishing the installation, it is requested to
test the correct operation of the condensate
removal pump.
Never try to run the pump "dry" without
water (pump destructive)
 Rinse thoroughly the condensate water
tray in order to eliminate all metallic
particles
and
foreign
bodies
connecting the detection unit.
 Position the detection unit in order to
collect the condensate from the air
conditioner
 Pour water into the condensate tray of the
air conditioner without overfilling
 Check the pump starts, pumps water, then
stops
3.a
MAINTENANCE.
Any maintenance on the condensate pump MUST BE DONE WITH THE POWER SUPPLIED
SWITCHED OFF.
At the beginning of the season, or regularly if the air conditioner is used all year long:
Remove the cap of the detection unit and the magnet. Clean inside the detection unit and the float
with water containing 5% bleach. Rinse thoroughly after use of a cleaning product.
Use only the supplied 3 core cable:
 Blue / Neutral
 Brown / Line
 Yellow+green / Earth
before
Then replace the float with the black spot facing up, and the filter. Replace the cap, always in the
direction of origin and do a full operational test.
3.b
SAFETY
 A thermal cut-out set with AUTO-RESET
 Connect the earth wire of the pump
 Product without alarm
SICCOM SAS strongly recommends fitting a high condensate level detector connected to an
audio alarm (Buzzer) or a visual one (Indicator) to avoid any overflow or interruption of refrigeration in
the event of an incident in the system or lack of maintenance. To do this, we recommend using the
SICCOM SAS ref DS1HTCC110 detector available from your retailer.
Warranty
Your pump is guaranteed to be in perfect working order at delivery. The model ECO FLOWATCH
Ref DE05LCC190 is guaranteed for one year (12 months) from the SICCOM SAS billing date against
all operating faults. In the case of detection of a fault, customers not located in France must return
the pump postage paid to the nearest SICCOM distributor. All products returned will be subject to a
complete analysis of origin and operation in relation to its traceability code and the technical
performances ascertained. If it is determined that the fault is unrelated to incorrect use of the pump
and that the installation instructions have been complied with, the product will be repaired or
replaced.
RESTRICTIONS:
Any implicit guarantee will be limited to the duration of the express guarantee specified above.
In all cases, the responsibility related to the SICCOM SAS warranty is limited to the
replacement or repair of the product supplied plus the cost of its transport to the original
delivery location.
N
EITHER THE VENDOR NOR THE MANUFACTURER IS RESPONSIBLE FOR INJURIES OR DAMAGES
DIRECTLY RELATED TO THE PRODUCT OR SUBSEQUENT TO ITS USE
,
TO LOSS OF PROFIT
LOSS OF TURNOVER
THE PRODUCT OR RESULTING FROM ITS USE
. T
INABILITY TO USE THE PRODUCT
HE USER AGREES THAT THIS SITUATION IS WITHOUT RECOURSE
.
OR COMPENSATION
THE WARRANTY WILL BE INVALIDATED IN THE FOLLOWING CASES:
-
Pump motor cover opened
-
Product connected to an incorrect supply voltage
Tank cable cut
-
Pump used dry (no liquid supply)
-
-
Pump used to circulate liquid other than condensates.
-
Incorrect use of the pump by the customer
Before using the product, the user must determine whether it is compatible with his or her
intended use of the product. They will be responsible for all risks and legal implications
resulting from its use or installation.
SICCOM SAS reserves the right to modify the product completely or partially without first
informing its customers about it
CONFORMITY CERTIFICATE SICCOM SAS
Z.I. Les Bordes 2 rue Gustave Madiot - 91070 Bondoufle - FRANCE declare that the ECO FLOWATCH
conformity with :
• EN 60 335-1
HINWEIS
Mit geringem Platzaufwand kann unsere ECO FLOWATCH
werden (Decken-, Wand- oder Konsole-Anlage), deren Kälteleistung 10 KW (36000 Btu, 2,8 Tonnen)
nicht überschreitet. Die ECO FLOWATCH
der Pumpeneinheit
dem Schwimmerschalter
(2 Niveaus Pumpen-Aus, Pumpen-Ein)
Allgemeine technische Daten :
Maximale Leistung :
13 Liter / Stunde
Maximale Fördermenge :
10 meter
Maximale Einsaugung :
1,5 Meter
Einspeisung der Pumpeneinheit :
220-240 V 50/60 Hz
Leistungsaufnahme der Pumpe :
19W
Relative Einschaltdauer:
100%
Thermische Sicherung :
Ja. Mit auto-restart.
Arbeitstemperatur :
5°C bis 45°C
Maximale Temperatur der Flüssigkeit: 35°C
Schutzklasse :
IP20
INSTALLATION
2.a
DIE PUMPENEINHEIT.
Die Einspeisung muss von einem anderen Netz als von der Klimaanlage herkommen.
Vor der Installation das Klimagerät spannungsfrei schalten.
Der Anschluss des Stromversorgungskabels muss von einem qualifizierten Fachmann unter
Berücksichtigung der geltenden Normen des Landes durchgeführt werden.
Dieses Netzkabel muss geerdet sein.
Nur das schwarze Kabel 3 gelieferte Fahrer zu benutzen und hat ein Schutz 10 auf der Linie.
(Die Norm NFC 15100 verlangt für die Wohnung einen hochempfindlichen FI-Schutzschalter (30 m
A).)
Bei Zweifeln und bei allen elektrischen Eingriffen wird empfohlen, einen qualifizierten Fachmann
heranzuziehen
SICCOM SAS haftet nicht für eventuelle durch eine unsachgemäße Installation entstandene
Schäden.
Wenn das Versorgungskabel beschädigt ist, muss es vom Hersteller, seinem Kundendienst oder
ähnlich qualifizierten Personen ersetzt werden, damit keine Gefährdung entsteht.
(
INCLUDING BUT NOT LIMITED
,
DAMAGE TO GOODS OR PERSONS DIRECTLY RELATED TO
)
OR ANY PREJUDICE ARISING FROM THE USE OF OR
D
®
einfach in jede Klimaanlage eingebaut
®
0 besteht aus den zwei folgenden Teilen :
®
®
is in
2

Publicidad

loading

Este manual también es adecuado para:

De05lcc190