1.
Specifications
The SCANMASKIN 32 WS is available with different power inputs and some options regarding
wet grinding. This is described in the different sections later on in this chapter.
1.1
Electrical specifications
To find the specifications that apply to your machine, check the information plate on the electri-
cal cabinet door.
Never connect the SCANMASKIN 32 WS to any other voltage or number of phases than de-
scribed in this specification.
The power source must be fused according to "External fuse" in this specification; also, the
cables used must be marked and rated in accordance with the fuse used. Failure to comply
with the correct fuses may cause fire or injuries.
Power choice
1
Power
Current
Voltage
Frequency
External fuse
3
Power inlet
4
Partnumber Inlet Eu 570057
Table 11 Electrical specifications
All models are CE-marked.
If using a generator see "2.6.2Using a generator"
1
This refers to different power choices. Note that a Scanmaskin 32 WS made for one choice of power must
be used with that particular choice.
2
Standard
Maximum current for the fuses used in the power source (i.e. the distribution box).
3
4
This is the standard inlet used. Machines sold outside of EU will be shipped either with a local standard
inlet or an adapter.
72
400 V 3~
230 V 3~
2
15 kW (20 hp)
11 kW (15 hp)
32 A
50 A
380 – 400 V 3~
200 – 240 V 3~
50/60 Hz ± 5%
50/60 Hz ± 5%
32 A
50 A
IEC 60309
IEC 60309 3P+E
3P+N+E 400V
250V 32A
32A
US 910912
US 910911