Measure dimension to fit

2
(30 mm)
Reference page 4 of these installation instructions for the acceptable pitch direction.
3

Final installation of the vent system

NOTE
Condensate can damage the water heater, please read carefully page 3 in
this installation manual.
7
1.15 (30 mm)
(whiter outer)
x = A + 2.5 (65 mm) minimum
Metal Inner Pipe
NOT E
First place innerwall plate to
slide terminal through
White Outer Pipe
- After cutting the appropriate length
slide the horizontal through the hole
in the wall. Position the first rubber
wall plate around the male end of the
termination.
- Slide the male end of the termination
in the Horizontal Discharge Adapter.
- Fill the gaps between the wall and the
vent pipe penetration with a weather
proof Sealant.
- Finally, position the second rubber
wall plate around the vent pipe, between
the termination and the exterior wall.