12. Troubleshooting
Fault
Possible cause
The compressor does
• No supply voltage.
not start.
• Insufficient supply voltage.
• Outside temperature is too low.
• Motor is overheated.
The compressor starts
• The safety valve (17) leaks.
but there is no pres-
sure.
• The seals are damaged.
• The drain plug for condensation water
(10) leaks.
The compressor
• The hose connections have a leak.
starts, pressure is
shown on the pressure
• A quick-lock coupling has a leak.
gauge, but the tools
do not start.
• Insufficient pressure set on the pressure
regulator (5).
26 | GB
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
Remedy
• Check the supply voltage, the power plug and
the socket-outlet.
• Make sure that the extension cable is not
too long. Use an extension cable with large
enough wires.
• Never operate with an outside temperature of
below +5° C.
• Allow the motor to cool down. If necessary,
remedy the cause of the overheating.
• Have a service center replace the safety valve
(17).
• Check the seals and have any damaged seals
replaced by a service center.
• Tighten the screw by hand. Check the seal on
the screw and replace if necessary.
• Check the compressed air hose and tools and
replace if necessary.
• Check the quick-lock coupling and replace if
necessary.
• Increase the set pressure with the pressure
regulator.