Airfusion Atlanta Installation Instructions
REMOTE CONTROL (Fig. 11)
LIGHT FUNCTION CONTROL (Fig. 11)
The GX53 LED lamp has a built-in 3 step dimming circuit.
- Initially turn ON the LED lamp with 100% brightness – press Light button (4) once on the remote.
- Press the Light button to switch OFF and then ON again, within 3 seconds for dimming to 50% brightness.
- Press the Light button to switch OFF and then ON again, within 3 seconds for dimming to 20% brightness.
(If the ON/OFF toggle switching is not completed within 3 seconds, the lamp will reset to 100% brightness)
PAIRING REMOTE AND RECEIVER – WHEN 1 DC CEILING FAN IS INSTALLED IN ONE LOCATION
NOTE: Ensure that you have installed a single pole disconnection switch in the fixed wiring for the fan.
NOTE: Ensure power to the receiver is ON prior to pairing the remote with the receiver.
•
Turn OFF the mains supply to the fan by on/off wall switch.
•
Install the batteries into the remote. Please make sure the polarity of the battery is correct.
•
Turn ON the power to the receiver.
•
Press and hold the "
ON to the receiver of the ceiling fan.
•
There will be a notification 'beep' sound from the receiver to indicate that the paring process is successful.
•
Turn ON and change the speed of the ceiling fan via the remote to check the operation and successful
paring.
11 | P a g e
USING YOUR CEILING FAN
" button on the remote for 10 seconds within 30 seconds of switching the power
(1) Reverse control
(2) Natural wind (The fan speed automatic cycle
between 1 to 6 speed)
(3) Speed control
(4) Light On/Off
(5) Fan On/Off
(6) 1.5V AAA battery x 2 pcs (Included)
Fig. 11