Descargar Imprimir esta página
Lutron Aviena AN-1PS Guia De Inicio Rapido
Lutron Aviena AN-1PS Guia De Inicio Rapido

Lutron Aviena AN-1PS Guia De Inicio Rapido

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Aviena
Single-Pole Switch
AN-1PS
3-Way Switch
AN-3PS
Rated at 120/277 V~ 60 Hz 15 A
Purchase Lutron wallplate separately.
• Easy-to-follow
Important Notes
Instructions
Please read before installing
• Instrucciones
Fáciles de Seguir
1. Connect only No. 12 or 14 gauge copper or copper clad
wire to switch. See device for strip length.
2. Do not connect aluminum wire to this device.
3. Install in accordance with all national and local electrical
030-921
codes.
4. Clean unit with a soft damp cloth only. Do not use any
chemical cleaners.
Multi-Unit Installations
• Easy-to-follow
When combining controls in a wallbox, remove all inner side sections prior to
Instructions
wiring (see below). Use pliers to bend side section up and down until it breaks
• Instrucciones
off. Repeat for each side section to be removed. Note: No derating required
Fáciles de Seguir
if ganged.
030-921
Each control has
inside section
removed.
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
1-800-523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1-610-282-3800
Fax +1-610-282-3090
Internet www.lutron.com
Limited Warranty
(Valid only in USA, Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place
of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR
FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM
MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL
DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION,
DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specifi c legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of
incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
This product may be covered under one or more of the following U.S. patents: 6,774,328; D526,969 and corresponding patents of other countries. U.S. and foreign
patents pending. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron is a registered trademark and Aviena is a
trademark of Lutron Electronics Co., Inc.
© 2007 Lutron Electronics Co., Inc.
English
TM
Middle control has
two side sections
removed.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 9/07 P/N 030-921 Rev. B
Lutron Technical Support Center
Installation
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
1
WARNING: Turn power OFF at circuit breaker or remove fuse.
2
Remove switch mounting screws. Pull switch from wall.
Turn screws
counterclockwise
to loosen.
3
Identify type of circuit.
SINGLE-POLE circuit:
Insulated wires connected to two
screws of the same color. Replace with
a single-pole or 3-way switch. Follow
Ground
(bare
wiring "Single-Pole Wiring" when
copper or
completing Step 6a.
green wire)
OR
3-WAY circuit:
Insulated wires connected to three
screws. One of these wires is
connected to a screw of a different-
color or labeled COMMON. Tag this
Ground
(bare
wire to identify it when wiring. Follow
copper or
wiring "3-Way Wiring" when completing
green wire)
Tag
Step 6b.
Different-colored
screw (Common)
Important Note: "Continued Hot"
Your wall switch may have two wires attached to the same screw (see
illustrations below for examples). Tape these two wires together before
disconnecting.
One wire in the
backwired hole and one
to the screw.
4
Disconnect switch wires.
Screw Terminals:
Turn screws
counterclockwise
to loosen.
OR
5
Prepare wires. Trim or strip wallbox wires to the length
indicated by the strip gauge on the back of the switch. Use the
same procedure to wire your new switch as was used with the
old switch (see Step 4 and below).
Push-in Terminals: Insert wires fully.
1/2"
NOTE: Push-in terminals are for
(13 mm)
use with #14 AWG solid copper wire
only. For aluminum wire, consult an
electrician. DO NOT use stranded or
twisted wire.
OR
Screw Terminals: Tighten securely.
Screw terminals are for use with solid
copper wire only. For aluminum wire,
consult an electrician. DO NOT use
stranded or twisted wire.
1-800-523-9466
24 hrs / 7 days
6
Wire the switch.
6a - Single-Pole Wiring
Ground
(Green screw)
Reference Wiring Diagram
Ground
Live
120/277 V~
Single-Pole
60 Hz
Switch
Neutral
6b - 3-Way Wiring
Ground
(Green screw)
Tag
Different-colored
screw (COMMON)
Reference Wiring Diagram
One continuous wire
Ground
to the screw.
Live
120/277 V~
3-Way
3-Way
60 Hz
Switch
Switch
Backwired:
Insert screwdriver and
pull wire out.
Neutral
7
Mount and align switch. Replace wallplate.
Turn screws
clockwise to start.
8
Turn power ON.
www.lutron.com
• Connect the bare copper or
green ground wire to the green
ground screw on the switch.
• Connect one of the insulated
wires removed from the switch
to either of the screws (or push-
in terminals) on the switch. If
two wires were taped together,
connect both wires to the
screw.
• Connect the other insulated
wire removed from the switch
to the other screw (or push-in
terminal) on the switch.
• Note: If you are replacing a
single-pole switch with a 3-
Way switch, the screw on the
opposite side of the different
colored screw, is not used.
Tighten it securely and follow
Light
instructions for single-pole
wiring.
OR
• Connect the green or bare
copper ground wire to the
green ground screw on the
switch.
• Connect the Tagged wire
removed from the switch to
the different-colored screw
(COMMON) (or push-in
terminal) on the switch.
• Connect one of the remaining
wires removed from the switch
to either of the remaining
screws (or push-in terminal) on
the switch.
• Connect the last wire removed
from the switch to the
Ground
remaining screw (or push-in
terminal) on the switch.
Light
Align switch and
tighten screws
clockwise.

Publicidad

loading

Resumen de contenidos para Lutron Aviena AN-1PS

  • Página 1 (Valid only in USA, Canada, Puerto Rico, and the Caribbean.) Push-in Terminals: Insert wires fully. Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place 1/2”...
  • Página 2 Encienda la corriente. Terminales de tornillos: Asegure terminales. Patentes pendientes en los E.U.A. y en otros países. Lutron es una marca registrada y Aviena es una marca de Lutron Electronics Co., Inc. NEC es una marca Agujeros para terminales de tornillos son registrada de National Fire Protection Association, Quincy, Massachusetts.

Este manual también es adecuado para:

Aviena an-3ps