Descargar Imprimir esta página
Lutron Qoto Q-1PS Guia De Inicio Rapido
Lutron Qoto Q-1PS Guia De Inicio Rapido

Lutron Qoto Q-1PS Guia De Inicio Rapido

Interruptor unipolar / de tres vías

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Single-Pole Switch
Q-1PS
3-Way Switch
Q-3PS
Rated at 120/277 V~ 60 Hz 15 A
Purchase Lutron wallplate separately.
• Easy-to-follow
Important Notes
Instructions
Please read before installing
• Instrucciones
Fáciles de Seguir
1. Connect only No. 12 or 14 AWG gauge copper or copper
clad wire to switch. See device for strip length.
2. Do not connect aluminum wire to this device.
3. Install in accordance with all national and local electrical
030-834
codes.
4. Clean unit with a soft damp cloth only. Do not use any
chemical cleaners.
Multi-Unit Installations
• Easy-to-follow
When combining controls in a wallbox, remove all inner side sections prior to
Instructions
wiring (see below). Use pliers to bend side section up and down until it breaks
• Instrucciones
off. Repeat for each side section to be removed. Note: No derating required if
Fáciles de Seguir
ganged.
030-834
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
1-800-523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1-610-282-3800
Fax +1-610-282-3090
Internet www.lutron.com
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place
of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM
PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE,
OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON'S LIABILITY
ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL
NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specifi c legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of
incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
This product may be covered under one or more of the following U.S. patents: 6,774,328; 7,105,763; D477,572 and corresponding patents of other countries. U.S.
and other patents pending. Lutron is a registered trademark and Qoto is a trademark of Lutron Electronics Co., Inc.
© 2006 Lutron Electronics Co., Inc.
English
Lutron Technical Support Center
Installation
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
1
WARNING: Turn power OFF at circuit breaker or remove fuse.
2
Remove switch mounting screws. Pull switch from wall.
3
Identify type of circuit.
Ground
(bare
copper or
green wire)
Ground
(bare
copper
Each control has
Middle control has
or green
inside section
two side sections
wire)
removed.
removed.
Important Note: Your wall switch may have two wires attached to the
same screw (see illustrations below for examples). Tape these two
wires together before disconnecting. When wiring, connect wires to the
dimmer the same way there were connected to the switch.
4
Disconnect switch wires.
5
Prepare wires. Trim or strip wallbox wires to the length
indicated by the strip gauge on the back of the switch. Use the
same procedure to wire your new switch as was used with the
old switch (see Step 4 and below).
1/2"
(13 mm)
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 10/06 P/N 030-834 Rev. B
1-800-523-9466
Turn screws
counterclockwise
to loosen.
SINGLE-POLE circuit:
Insulated wires connected to two
screws of the same color. Replace with
a single-pole or 3-way switch. Follow
wiring "Single-Pole Wiring" when
completing Step 6a.
OR
3-WAY circuit:
Insulated wires connected to three
screws. One of these wires is
connected to a screw of a different-
color or labeled COMMON. Tag this
wire to identify it when wiring. Follow
wiring "3-Way Wiring" when completing
Tag
Step 6b.
Different-colored
screw (Common)
One wire in the
One continuous wire
backwired hole and one
to the screw.
to the screw.
Backwired:
Screw Terminals:
Insert screwdriver and
Turn screws
pull wire out.
counterclockwise
to loosen.
OR
Push-in Terminals: Insert wires fully.
NOTE: Push-in terminals are for
use with #14 AWG solid copper wire
only. For aluminum wire, consult an
electrician. DO NOT use stranded or
twisted wire.
OR
Screw Terminals: Tighten securely.
Screw terminals are for use with solid
copper wire only. For aluminum wire,
consult an electrician. DO NOT use
stranded or twisted wire.
24 hrs / 7 days
www.lutron.com
6
Wire the switch.
6a - Single-Pole Wiring
• Connect the bare copper or
Ground
(Green screw)
green ground wire to the green
ground screw on the switch.
• Connect one of the insulated
wires removed from the
switch to either of the screws
(or push-in terminals) on the
switch.
• Connect the other insulated
wire removed from the switch
to the other screw (or push-in
terminal) on the switch.
Reference Wiring Diagram
• Note: If you are replacing
Ground
a single-pole switch with a
3-way switch, the screw on the
opposite side of the different
Live
colored screw, is not used.
120/277 V~
Tighten it securely and follow
60 Hz
Single-Pole
instructions for single-pole
Switch
wiring.
Light
Neutral
6b - 3-Way Wiring
• Connect the green or bare
Ground
copper ground wire to the
(Green screw)
green ground screw on the
switch.
• Connect the Tagged wire
removed from the switch to
the different-colored screw
(COMMON) (or push-in
terminal) on the switch.
• Connect one of the remaining
Tag
wires removed from the switch
Different-colored
to either of the remaining
screw (COMMON)
screws (or push-in terminal) on
the switch.
Reference Wiring Diagram
• Connect the last wire removed
Ground
Ground
from the switch to the
remaining screw (or push-in
terminal) on the switch.
Live
120/277 V~
3-Way
3-Way
60 Hz
Switch
Switch
Light
Neutral
7
Mount and align switch. Replace wallplate.
Turn screws
clockwise to start.
8
Turn power ON.
OR
Align switch and
tighten screws
clockwise.

Publicidad

loading

Resumen de contenidos para Lutron Qoto Q-1PS

  • Página 1 Push-in Terminals: Insert wires fully. 1/2” Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place NOTE: Push-in terminals are for...
  • Página 2 Encienda la corriente. Terminales de tornillos: Asegure terminales. otros países. Patentes pendientes en los E.U.A. y en otros países. Lutron es una marca registrada y Fassada y Qoto son marcas registradas de Lutron Electronics Co., Agujeros para terminales de tornillos son para Inc.

Este manual también es adecuado para: