Installing the safety filter sack
Release and remove the suction head.
Illustration
Insert the safety filter sack.
Illustration
Pull the safety filter sack over the con-
tainer.
Insert and lock the suction head.
Installing the dust disposal bag
Illustration
Note: The opening of the disposal bag
must be pulled all the way over the ledge of
the suction support.
Release and remove the suction head.
Attach disposal bag.
Pull disposal bag over the container.
Insert and lock the suction head.
Wet vacuum cleaning
DANGER
No dusts hazardous to health should be
sucked in during wet vacuuming.
Inserting the rubber lips
Illustration
Remove the brush strips.
Install the rubber lips.
Close the suction connection
Illustration
Precisely fit the plug into the suction
connection.
Insert the plug up to the stop.
Removing the safety filter sack
Release and remove the suction head.
Illustration
Pull over the safety filter sack.
Take off the protective film and close
the ventilation hole with a self-adhesive
tab.
Illustration
Pull the safety filter sack towards the
rear.
Seal the suction connection opening of
the safety filter bag tightly with closing
slides.
Illustration
Securely close the safety filter bag with
the attached cable tie.
Remove the safety filter bag.
Wipe the inside of the container using a
damp cloth.
Dispose of the safety filter bag in a dust-
tight bag according to the statutory pro-
visions.
Insert and lock the suction head.
– To suck wet dirt, always remove the
safety filter bag.
Removing the dust disposal bag
Illustration
Release and remove the suction head.
Put the disposal bag over.
Pull the opening of the disposal bag out
toward the back over the suction sup-
port.
Seal the dust bag tightly with cable ties
under the suction connection opening
and the ventilation hole.
Remove disposal bag.
Wipe the inside of the container using a
damp cloth.
Dispose of the disposal bag according
to the local provisions.
Insert and lock the suction head.
– To suck wet dirt, always remove the dis-
posal bag.
General
WARNING
The two flat fold filters may never be re-
moved during vacuuming.
– If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
– If the maximum liquid level is reached
the appliance will turn off automatically.
– In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
– 4
EN
21