WLA08-pg1-124
22/05/08
19:53
Functions not available
H.I. Alert, setting slope in manual mode, or moving the scan or
plumb point are not available in wall mount mode. Exit wall mount
mode to use these functions.
Detaching the mount
Screw both knobs (1) all the way out to detach the mount from the laser.
Troubleshooting
If the laser does not move on the mount, check that the knobs (1)
are tight enough to make the power contact for the motor. The
mount can also be detached to check that the contacts where the
laser and mount are fastened are clean.
2.7.2 Using the laser with wall mount
on a ceiling grid
Setup:
1. Check that the laser and mount are connected securely. The
knobs (1) should be turned fairly tight to make contact for the
motor, although do not overtighten. Check that the safety clip
is well engaged.
2. Flip down the support plate (8).
3. Release the clamp (2) on top of the adjustable plate (3).
4. Lock the clamp against the ceiling grid. The grid should not
exceed 1/8" 3mm thickness.
5. If the foot on the support plate is not touching the wall, use the
screw (9) to adjust.
To move the laser up or down with the remote control:
1. Turn on the laser and wait for it to self-level. The head must be
rotating before you can enter wall mount mode.
2. Press the scanning key and hold it for several seconds until you
hear 4 beeps. This will put the laser in "wall mount mode". All
three LEDs will blink.
3. Press the + key to move the laser up; press - to move the laser
down. Holding the key will result in fast movement; short clicks will
move the laser more precisely.
If you don't raise or lower the wall mount for 5 minutes, the laser
will go back to its previous mode. You'll hear a 4-second beep.
2.7.3 Using the motorized mount
and laser on the floor
1. Check that the laser and mount are connected securely. The
10
Page 10
knobs (1) should be turned fairly tight to make contact for the
motor, although do not overtighten.
2. Flip down the support plate (8) and place the laser in vertical
mode on the floor.
3. If the support plate is not level, use the screw (9) to adjust.
4. Press the scanning keys (15 and 13) and hold them for a few
seconds until you hear 4 beeps. This will put the laser in "wall
mount mode". All three LEDs will blink.
5. Press the + or - keys to move the laser back and forth. Holding
the key will result in fast movement; short clicks will move the laser
more precisely.
If you don't move the mount for 5 minutes, the laser will go back to
its previous mode. You'll hear a 4-second beep.
2.8 Squaring
After placing the laser in vertical position, the plumb beam out the
top of the head can be moved to the left or right. This is necessary
to do squaring for installing walls and partitions.
To position the rotating plane perpendicular to a reference line:
1. Place the laser on the ground so that the index notch on top of
the adjustable plate is over your reference point.
2. After the laser has self-leveled, stop the head rotation. Turn the
head down so that the beam is on the adjustable plate.
3. Hold the scan key several seconds to put in wall mount mode.
Use the < or > keys (13 and 14) to adjust the laser so that the
beam is on the reference point.
4. Exit from wall mount mode using the scan key. Align the beam
projecting from the top of the head to your second reference point
using the < or > keys (13 or 14). This beam is 90° or square to the
other vertical plane beam.
5. Start rotation of the head.
It is very important to check while you are using the
laser that it has not been moved and that your setting
is still accurate.
GB F E D I N FIN
11