Installation and safety instructions
1. The immersion heater can be used for the auxil-
iary heating of water in closed or open containers
only.
2. During operation, the heating elements and sen-
sor protection tube must be surrounded by suf-
ficient water on all sides. The thermally induced
water flow must not be impeded.
3. The immersion heater must be installed in hori-
zontal position. To allow installation, ensure that
there is sufficient space in front of the tank sleeve
corresponding to the installation length + 50 mm.
4. The unheated zone of the heating elements is
100 mm from the heating element gasket.
5. Before installation, maintenance and service work
to the immersion heater, the power supply must
be disconnected.
6. The ambient temperature at the immersion heater
casing must not exceed 80°C.