ENglISh
Water connection
The installation and connection instructions as well
as the directions for use for the water heater (boiler)
must be followed. For pressurised connections, a
certified membrane safety valve or a membrane
safety valve combination is required. For unpressu-
rised connections, a return valve, a stop valve as well
as service fittings for unpressurised connections are
required. Dry heating must be avoided!
putting into operation
The water container must be filled with water be-
fore the electricity is turned on. The first-time heat-
ing of the system must be monitored to make sure
that the thermostat cuts out when the temperature
setting is reached. For pressurised connections, the
expanded water produced in the interior boiler drips
out through the safety valve during the heating
process. For unpressurized connections, the water
drips from the overflow mixing tap.
Note: The automatic cut-out function of the thermo-
stat must be checked and that only original spare
parts can be used.
Directions for use
1. Depending on the lime content of the water and
the operating temperature, it may be necessary
to descale the heating elements regularly. We
Variant
Item no.
SH-1.5
A907 21
SH-2.0
A907 22
Sh-2.5
A907 23
SH-3.0
A907 24
SH-3.8
A907 25
SH-4.5
A907 26
SH-6.0
A907 27
SH-7.5
A907 28
SH-9.0
A907 29
Nominal
Supply
power
voltage
kW
V
1.5
230
2.0
230/400
2.5
230/400
3.0
230/400
3.8
400
4.5
400
6.0
400
7.5
400
9.0
400
recommend to install a water softening unit or
a temperature setback, as described in the fol-
lowing. Please note that damage to the heating
element caused by calcification invalidates the
guarantee.
2. The water temperature in the tank can be
adjusted using the temperature control. The
maximum temperature setting is about 75°C.
The minimum setting is about 9°C and thus also
serves as anti freeze function. The differential gap
amounts to about 10°C. When set to 75°C, the
temperature will drop to about 65°C, before the
heating function switches on again. To prevent
a rapid calcification of the heating element, we
recommend a temperature setting between 55
and 65°C. This corresponds to the position of
the temperature setting shown in the illustration
below.
3. If a defect occurs during operation, contact a
qualified electrician.
Installation
depth from
gasket
mm
320
320
390
390
430
470
620
720
780
ZTS 0101
ca.°C
Minimum
power
volume, tank
consumption
l
A
80
6.4
80
8.7/3.0
80
11.0/3.7
80
13.0/4.4
80
5.5
90
6.5
100
8.7
200
11.0
240
13.0
9 VELUX